Literature DB >> 21477039

Early hardness of self-adhesive resin cements cured under indirect resin composite restorations.

Isabel Giráldez1, Laura Ceballos, Miguel A Garrido, Jesús Rodríguez.   

Abstract

PURPOSE: To determine the influence of curing mode on the surface hardness of seven resin cements used to lute indirect composite restorations.
MATERIALS AND METHODS: Seven commercial dual-curing resin cements were tested: two were total-etch (RelyX ARC [3M ESPE, St. Paul, MN, USA] and Variolink II [Ivoclar Vivadent, Schaan, Liechtenstein]); one was self-etch (Multilink Automix [Ivoclar Vivadent]), and four were self-adhesive (RelyX Unicem [3M ESPE], Maxcem Elite [Kerr Corp., Orange, CA, USA], SmartCem2 [Dentsply, Detrey, GmbH, Konstanz, Germany], and G-Cem [GC CORPORATION, Itabashi-Ku, Tokyo, Japan]). Three specimens (0.5 × 6.5mm) of each material were prepared for each of three experimental groups: Group 1 (cements allowed to self cure); Group 2 (cements light-cured for 40 seconds); and Group 3 (cements light-cured for 80 seconds). All specimens were cured through a 4-mm-thick composite cylinder (Filtek Z250-A3). Surface microhardness numbers were determined at 20 min after preparation. Results were analyzed by two-way analysis of variance and Student-Newman-Keuls tests (p<0.05).
RESULTS: Superficial hardness was significantly influenced by the resin cement tested (p<0.0001), the curing mode (p<0.0001), and their interaction (p<0.0001). RelyX ARC exhibited the highest mean microhardness values regardless of the curing mode. Light-curing significantly increased the microhardness of all resin cements studied, and these values increased even further with a doubling of irradiation time. Self-adhesive cements exhibited different behavior according to the curing mode. RelyX Unicem was highly sensitive to light irradiation, showing the lowest mean values in the self-curing mode. After light irradiation for 40 or 80 seconds, Maxcem Elite exhibited the lowest mean hardness values of all the resin cements tested.
CONCLUSION: The microhardness of resin cements is highly dependent on the brand. Dual-curing resin cements should always be light irradiated for longer periods than that recommended by manufacturers. CLINICAL SIGNIFICANCE: Dual-curing resin cements should always be light-cured for longer irradiation times, as light irradiation for 80 seconds yields the highest microhardness values in comparison with self-curing or light irradiation for 40 seconds. However, some self-adhesive resin cements exhibit low microhardness values when used to cement 4-mm-thick indirect composite restorations regardless of the curing mode applied.
© 2011, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2011, WILEY PERIODICALS, INC.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21477039     DOI: 10.1111/j.1708-8240.2011.00408.x

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  5 in total

1.  Bond strength of self-adhesive resin cements to different treated indirect composites.

Authors:  M Victoria Fuentes; Laura Ceballos; Santiago González-López
Journal:  Clin Oral Investig       Date:  2012-05-23       Impact factor: 3.573

2.  Influence of proximal box elevation on bond strength of composite inlays.

Authors:  Dayana Da Silva Gonçalves; María Cura; Laura Ceballos; Mª Victoria Fuentes
Journal:  Clin Oral Investig       Date:  2016-03-11       Impact factor: 3.573

3.  Influence of thickness and translucency of lithium disilicate ceramic on degree of conversion of resinous materials.

Authors:  Priscila-Christiane-Suzy Liporoni; Alcira-Cinthia-Rodríguez Ponce; Maiara-Rodrigues de Freitas; Rayssa-Ferreira Zanatta; Maria-Clara-Santos Pereira; Anderson Catelan
Journal:  J Clin Exp Dent       Date:  2020-08-01

4.  Degree of conversion and microhardness of resin cements photoactivated through glass ceramic.

Authors:  Carolina-Nemesio-de Barros Pereira; Cláudia-Silami Magalhães; Frederico-Santos Lages; Raquel-da Conceição Ferreira; Emerson-Hamilton da Silva; Rodrigo-Richard da Silveira; Elaine-Carballo-Siqueira Corrêa; Cristiano-Leite Fantini; Allyson-Nogueira Moreira
Journal:  J Clin Exp Dent       Date:  2021-11-01

5.  Effect of indirect composite treatment microtensile bond strength of self-adhesive resin cements.

Authors:  María-Victoria Fuentes; Nuria Escribano; Bruno Baracco; Martin Romero; Laura Ceballos
Journal:  J Clin Exp Dent       Date:  2016-02-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.