Literature DB >> 21476205

Application of sphygmography to detection of dyspepsia and the rhinitis.

Chin-Ming Huang1, Hsien-Cheh Chang, Shung-Te Kao, Tsai-Chung Li, Yin-Tzu Liao, Ching-Chuan Wei, Chiachung Chen.   

Abstract

Diagnosis by radial arterial pulse is very important in Traditional Chinese Medicine (TCM). The objective of this study is to evaluate the effects of detection time and position on the parameters of time- and frequency-domain of radial pulse wave and to differentiate between Dyspepsia and Rhinitis by the statistical analysis of two signal types. A sphygmograph was developed to record radial pressure pulse for spectral analysis. The measurements were expressed as the pressure wave and its frequency. In this study, 135 subjects including the controls, Dyspepsias and Rhinitis were enrolled in this study. The signals were taken from three diagnosis positions of both wrists. Seven parameters of pressure wave and two parameters of spectrum analysis were evaluated by ANOVA test and Tukey's test. The results showed that the effects of detection time and position on the parameters taken from pulse wave were inconsistent. No regular rules or relationship could be established. The power spectra of 10-50 Hz and 13-50 Hz from sphygmography revealed a significant effect of health status, position and their interaction. There was a significant difference in the power spectra of 13-50 Hz between the control and Rhinitis, as well as between the control and Dyspepsia at right Guan position. The results of this study strongly suggest that the spectrum of sphygmogram might be more helpful than the pressure wave signals for detection of Dyspepsia and Rhinitis.

Entities:  

Mesh:

Year:  2011        PMID: 21476205     DOI: 10.1142/S0192415X11008816

Source DB:  PubMed          Journal:  Am J Chin Med        ISSN: 0192-415X            Impact factor:   4.667


  3 in total

1.  Radial Pulse and Electrocardiography Modulation by Mild Thermal Stresses Applied to Feet: An Exploratory Study with Randomized, Crossover Design.

Authors:  Jang-Han Bae; Boncho Ku; Young Ju Jeon; Hyunho Kim; Jihye Kim; Haebeom Lee; Jong Yeol Kim; Jaeuk U Kim
Journal:  Chin J Integr Med       Date:  2017-11-17       Impact factor: 1.978

2.  Distal Acupoints Outperform Proximal Acupoints in Treating Knee Osteoarthritis: A Randomized Controlled Trial.

Authors:  Wan-Zhen Yu; Chin-Ming Huang; Hui-Ping Ng; Yu-Chen Lee
Journal:  Evid Based Complement Alternat Med       Date:  2021-08-18       Impact factor: 2.629

3.  New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices.

Authors:  Jang-Han Bae; Young Ju Jeon; Jong Yeol Kim; Jaeuk U Kim
Journal:  Evid Based Complement Alternat Med       Date:  2013-09-26       Impact factor: 2.629

  3 in total