Literature DB >> 21472555

A combined desorption ionization by charge exchange (DICE) and desorption electrospray ionization (DESI) source for mass spectrometry.

Chang-Ching Chan1, Mark S Bolgar, Scott A Miller, Athula B Attygalle.   

Abstract

A source that couples the desorption ionization by charge exchange (DICE) and desorption electrospray ionization (DESI) techniques together was demonstrated to broaden the range of compounds that can be analyzed in a single mass spectrometric experiment under ambient conditions. A tee union was used to mix the spray reagents into a partially immiscible blend before this mixture was passed through a conventional electrospray (ES) probe capillary. Using this technique, compounds that are ionized more efficiently by the DICE method and those that are ionized better with the DESI procedure could be analyzed simultaneously. For example, hydroquinone, which is not detected when subjected to DESI-MS in the positive-ion generation mode, or the sodium adduct of guaifenesin, which is not detected when examined by DICE-MS, could both be detected in one experiment when the two techniques were combined. The combined technique was able to generate the molecular ion, proton and metal adduct from the same compound. When coupled to a tandem mass spectrometer, the combined source enabled the generation of product ion spectra from the molecular ion and the [M + H](+) or [M + metal](+) ions of the same compound without the need to physically change the source from DICE to DESI. The ability to record CID spectra of both the molecular ion and adduct ions in a single mass spectrometric experiment adds a new dimension to the array of mass spectrometric methods available for structural studies. © American Society for Mass Spectrometry, 2011

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21472555     DOI: 10.1007/s13361-010-0001-z

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  15 in total

1.  Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids.

Authors:  Jentaie Shiea; Min-Zon Huang; Hsiu-Jung Hsu; Chi-Yang Lee; Cheng-Hui Yuan; Iwona Beech; Jan Sunner
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

2.  Direct, trace level detection of explosives on ambient surfaces by desorption electrospray ionization mass spectrometry.

Authors:  Zoltán Takáts; Ismael Cotte-Rodriguez; Nari Talaty; Huanwen Chen; R Graham Cooks
Journal:  Chem Commun (Camb)       Date:  2005-02-07       Impact factor: 6.222

3.  Principal component analysis of urine metabolites detected by NMR and DESI-MS in patients with inborn errors of metabolism.

Authors:  Zhengzheng Pan; Haiwei Gu; Nari Talaty; Huanwen Chen; Narasimhamurthy Shanaiah; Bryan E Hainline; R Graham Cooks; Daniel Raftery
Journal:  Anal Bioanal Chem       Date:  2006-07-05       Impact factor: 4.142

4.  Desorption ionization by charge exchange (DICE) for sample analysis under ambient conditions by mass spectrometry.

Authors:  Chang-Ching Chan; Mark S Bolgar; Scott A Miller; Athula B Attygalle
Journal:  J Am Soc Mass Spectrom       Date:  2010-05-05       Impact factor: 3.109

5.  Mass spectrometry sampling under ambient conditions with desorption electrospray ionization.

Authors:  Zoltán Takáts; Justin M Wiseman; Bogdan Gologan; R Graham Cooks
Journal:  Science       Date:  2004-10-15       Impact factor: 47.728

6.  Desorption atmospheric pressure photoionization.

Authors:  Markus Haapala; Jaroslav Pól; Ville Saarela; Ville Arvola; Tapio Kotiaho; Raimo A Ketola; Sami Franssila; Tiina J Kauppila; Risto Kostiainen
Journal:  Anal Chem       Date:  2007-09-06       Impact factor: 6.986

7.  Carbohydrate and steroid analysis by desorption electrospray ionization mass spectrometry.

Authors:  Tiina J Kauppila; Nari Talaty; Ayanna U Jackson; Tapio Kotiaho; Risto Kostiainen; R Graham Cooks
Journal:  Chem Commun (Camb)       Date:  2008-05-08       Impact factor: 6.222

8.  Rapid screening of anabolic steroids in urine by reactive desorption electrospray ionization.

Authors:  Guangming Huang; Hao Chen; Xinrong Zhang; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2007-10-05       Impact factor: 6.986

9.  Ambient analysis of saturated hydrocarbons using discharge-induced oxidation in desorption electrospray ionization.

Authors:  Chunping Wu; Kuangnan Qian; Marcela Nefliu; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2009-11-13       Impact factor: 3.109

10.  Rapid, direct analysis of cholesterol by charge labeling in reactive desorption electrospray ionization.

Authors:  Chunping Wu; Demian R Ifa; Nicholas E Manicke; R Graham Cooks
Journal:  Anal Chem       Date:  2009-09-15       Impact factor: 6.986

View more
  1 in total

1.  Aliphatic hydrocarbon spectra by helium ionization mass spectrometry (HIMS) on a modified atmospheric-pressure source designed for electrospray ionization.

Authors:  Zhihua Yang; Athula B Attygalle
Journal:  J Am Soc Mass Spectrom       Date:  2011-05-10       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.