Literature DB >> 21471414

Effect of calcium phosphate bone cement augmentation on volar plate fixation of unstable distal radial fractures in the elderly.

Jae Kwang Kim1, Young Do Koh, Seung Hwan Kook.   

Abstract

BACKGROUND: Calcium phosphate bone cement increases the stability of implant-bone constructs in patients with an osteoporotic fracture. The purpose of this randomized study was to determine whether augmentation of volar locking plate fixation with calcium phosphate bone cement has any benefit over volar locking plate fixation alone in patients older than sixty-five years of age who have an unstable distal radial fracture.
METHODS: Forty-eight patients (fifty unstable distal radial fractures) were recruited for this study. The mean patient age was seventy-three years. Surgical procedures were randomized between volar locking plate fixation alone (Group 1) and volar locking plate fixation with injection of calcium phosphate bone cement (Group 2). The patients were assessed clinically at three and twelve months postoperatively. Clinical assessments included determinations of grip strength, wrist motion, wrist pain, modified Mayo wrist scores, and Disabilities of the Arm, Shoulder and Hand (DASH) scores. Radiographic evaluations were performed immediately postoperatively and at one year following surgery. The adequacy of the reduction was assessed by measuring radial inclination, volar angulation, and ulnar variance.
RESULTS: The two groups were comparable with regard to age, sex, fracture type, injury mechanism, and bone mineral density. No significant differences were observed between the groups with regard to the clinical outcomes at the three or twelve-month follow-up examination. No significant intergroup differences in radiographic outcomes were observed immediately after surgery or at the one-year follow-up visit. Furthermore, no complication-related differences were observed, and there were no nonunions.
CONCLUSIONS: Augmentation of metaphyseal defects with calcium phosphate bone cement after volar locking plate fixation offered no benefit over volar locking plate fixation alone in elderly patients with an unstable distal radial fracture.
© 2011 by the Journal of Bone and Joint Surgery, Incorporated

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21471414     DOI: 10.2106/JBJS.J.00613

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  11 in total

1.  Opening wedge distal femoral varus osteotomy using the Puddu plate and calcium phosphate bone cement.

Authors:  T R Dewilde; J Dauw; H Vandenneucker; J Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-05       Impact factor: 4.342

2.  Outcomes after volar plate fixation of low-grade open and closed distal radius fractures are similar.

Authors:  Jae Kwang Kim; Sang Doo Park
Journal:  Clin Orthop Relat Res       Date:  2013-01-24       Impact factor: 4.176

Review 3.  Orthobiologics in the augmentation of osteoporotic fractures.

Authors:  J Tracy Watson; Daemeon A Nicolaou
Journal:  Curr Osteoporos Rep       Date:  2015-02       Impact factor: 5.096

4.  The Effect of Displaced Dorsal Rim Fragment in a Distal Radius Fracture.

Authors:  Jae Kwang Kim; Yeo-Hon Yun; Dong Jun Kim
Journal:  J Wrist Surg       Date:  2016-01-06

Review 5.  Treatment goals for distal radius fractures in 2018: recommendations and practical advice.

Authors:  F Loisel; M Bourgeois; T Rondot; J Nallet; M Boeckstins; S Rochet; G Leclerc; L Obert; D Lepage
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-04-16

Review 6.  The "Three in One" Bone Repair Strategy for Osteoporotic Fractures.

Authors:  Xiao Chen; Yan Hu; Zhen Geng; Jiacan Su
Journal:  Front Endocrinol (Lausanne)       Date:  2022-06-09       Impact factor: 6.055

Review 7.  [Cement augmentation and bone graft substitutes-Materials and biomechanics].

Authors:  Boyko Gueorguiev; Mark Lenz
Journal:  Unfallchirurgie (Heidelb)       Date:  2022-04-29

8.  The use of bone cement in difficult distal radius fractures.

Authors:  Mithun Neral; Mario Solari; Chad Purnell; Ronit Wollstein
Journal:  Hand (N Y)       Date:  2013-12

9.  Calcium phosphate cement augmentation after volar locking plating of distal radius fracture significantly increases stability.

Authors:  Hans Kainz; Enrico Dall'Ara; Anna Antoni; Heinz Redl; Philippe Zysset; Patrick Weninger
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-08-04

10.  Increased risk of hip fractures in patients with dementia: a nationwide population-based study.

Authors:  Hao-Kuang Wang; Chao-Ming Hung; Sheng-Hsiang Lin; Yi-Cheng Tai; Kang Lu; Po-Chou Liliang; Chi-Wei Lin; Yi-Che Lee; Pei-Hsuan Fang; Li-Ching Chang; Ying-Chun Li
Journal:  BMC Neurol       Date:  2014-09-12       Impact factor: 2.474

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.