Susceptibility-weighted angiography (SWAN) of cerebral veins and arteries compared to TOF-MRA.

T Boeckh-Behrens1, J Lutz, N Lummel, M Burke, T Wesemann, V Schöpf, H Brückmann, J Linn.   

Abstract

PROBLEM: High resolution, non-contrast imaging of both cerebral veins and arteries by use of gradient echo T2 star weighted angiography (SWAN) is a new method for susceptibility-weighted imaging with short acquisition times. We assessed the potential of this sequence for the depiction of both cerebral veins and arteries.
METHODS: 15 healthy volunteers were included in the study. MRI was performed on a 3T MR scanner using the following sequences: (1) a 3D multi-echo gradient echo T2 star weighted angiography (SWAN), (2) an arterial 3D TOF MR angiography and (3) a venous 2D TOF. With regard to the SWAN sequence, both MinIP and MIP images were reconstructed and systematically compared to MIP reconstructions of the artTOF and the venTOF. To suggest possible clinical implications of our findings, we additionally included two illustrative cases.
RESULTS: With regard to the visualization of the cerebral veins, the MinIP reconstructions of the SWAN sequence were considerably superior compared to the venTOF. Concerning the depiction of the main segments of the big cerebral arteries the value of the MIP reconstructions of the SWAN was comparable to that of the artTOF with limitations in the homogenity and in the depiction of smaller arteries.
CONCLUSIONS: SWAN allows for high-resolution visualization of both cerebral veins and arteries in one sequence without application of contrast agent and with significantly shortened scan time compared to the combined scan time of TOF-MRA and TOF-MRV. By use of either MinIP or MIP reconstructions, the arteries can be distinguished from the veins.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21466929     DOI: 10.1016/j.ejrad.2011.02.057

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  19 in total

1.  MR imaging findings in intracranial dural arteriovenous fistula shunt with retrograde cortical venous drainage using susceptibility-weighted angiography.

Authors:  J Hodel; S Gerber; M Zins; M Rodallec; X Leclerc; R Blanc; A Rahmouni
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-13       Impact factor: 3.825

2.  The expression of P2X₇ receptors in EPCs and their potential role in the targeting of EPCs to brain gliomas.

Authors:  Jingqin Fang; Xiao Chen; Shunan Wang; Tian Xie; Xuesong Du; Heng Liu; Sumei Wang; Xue Li; Jinhua Chen; Bo Zhang; Huaping Liang; Yizeng Yang; Weiguo Zhang
Journal:  Cancer Biol Ther       Date:  2015-04-03       Impact factor: 4.742

3.  Enhanced susceptibility-weighted angiography (ESWAN) of cerebral arteries and veins at 1.5 Tesla.

Authors:  L Chen; J Zhang; Q-X Wang; L Peng; X Luo; W-Z Zhu; A K Roshan; J-P Qi; H Wang
Journal:  Br J Radiol       Date:  2014-05-02       Impact factor: 3.039

4.  Susceptibility Vessel Sign and Cardioembolic Etiology in the THRACE Trial.

Authors:  Romain Bourcier; Imad Derraz; Béatrice Delasalle; Marine Beaumont; Sebastien Soize; Laurence Legrand; Hubert Desal; Serge Bracard; Olivier Naggara; Catherine Oppenheim
Journal:  Clin Neuroradiol       Date:  2018-06-12       Impact factor: 3.649

Review 5.  Diagnosis of Cerebral Amyloid Angiopathy: Evolution of the Boston Criteria.

Authors:  Steven M Greenberg; Andreas Charidimou
Journal:  Stroke       Date:  2018-01-15       Impact factor: 7.914

6.  Comparison of 3D multi-echo gradient-echo and 2D T2* MR sequences for the detection of arterial thrombus in patients with acute stroke.

Authors:  Jérôme Hodel; Xavier Leclerc; Wassef Khaled; Ruben Tamazyan; Mathieu Rodallec; Sophie Gerber; Raphael Blanc; Mohamed Benadjaoud; Oriane Lambert; Cécile Rabrait; Mathieu Zuber; Alain Rahmouni; Marc Zins
Journal:  Eur Radiol       Date:  2013-11-20       Impact factor: 5.315

7.  Cerebral vein changes in relapsing-remitting multiple sclerosis demonstrated by three-dimensional enhanced T₂-weighted angiography at 3.0 T.

Authors:  Chun Zeng; Xuan Chen; Yongmei Li; Yu Ouyang; Fajin Lv; Reshiana Rumzan; Zhongping Wang
Journal:  Eur Radiol       Date:  2012-09-12       Impact factor: 5.315

8.  Quantification of Phase Values of Cerebral Microbleeds in Hypertensive Patients Using ESWAN MRI.

Authors:  L F Guo; J Geng; M H Qiu; C H Mao; C Liu; L Cui
Journal:  Clin Neuroradiol       Date:  2013-01-20       Impact factor: 3.649

9.  Susceptibility-weighted angiography for the detection of high-flow intracranial vascular lesions: preliminary study.

Authors:  Jérôme Hodel; Raphaël Blanc; Mathieu Rodallec; Antoine Guillonnet; Sophie Gerber; Silvia Pistocchi; Rémi Sitta; Cécile Rabrait; Mathieu Zuber; Jean-Pierre Pruvo; Marc Zins; Xavier Leclerc
Journal:  Eur Radiol       Date:  2012-10-31       Impact factor: 5.315

10.  Susceptibility-weighted MR sequence for the evaluation of ovarian masses with torsion.

Authors:  Mayumi Takeuchi; Kenji Matsuzaki; Masafumi Harada
Journal:  Br J Radiol       Date:  2020-04-01       Impact factor: 3.039