Abstract

A specific 2-year program to monitor and test both the vadose zone and the saturated zone, coupled with a numerical analysis, was performed to evaluate the overall performance of slurry wall systems for containment of contaminated areas. Despite local physical confinement (slurry walls keyed into an average 2-m-thick aquitard), for at least two decades, high concentrations of chlorinated solvents (up to 110 mg l(-1)) have been observed in aquifers that supply drinking water close to the city of Milan (Italy). Results of monitoring and in situ tests have been used to perform an unsaturated-saturated numerical model. These results yielded the necessary quantitative information to be used both for the determination of the hydraulic properties of the different media in the area and for the calibration and validation of the numerical model. Backfill material in the shallower part of the investigated aquifer dramatically affects the natural recharge of the encapsulated area. A transient simulation from wet to drought periods highlights a change in the ratio between leakages from lateral barriers that support a specific scenario of water loss through the containment system. The combination of monitoring and modelling allows a reliable estimate of the overall performance of the physical confinement to be made without using any invasive techniques on slurry wall.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21465133     DOI: 10.1007/s10661-011-1990-1

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  3 in total

1.  Moisture monitoring in waste disposal surface barriers.

Authors:  Alex Brandelik; Christof Huebner
Journal:  Environ Monit Assess       Date:  2003-05       Impact factor: 2.513

2.  Modeling the long-term perfomance of waste containment systems.

Authors:  Hilary I Inyang
Journal:  Environ Sci Technol       Date:  2004-09-01       Impact factor: 9.028

3.  Combining pump-and-treat and physical barriers for contaminant plume control.

Authors:  Peter Bayer; Michael Finkel; Georg Teutsch
Journal:  Ground Water       Date:  2004 Nov-Dec       Impact factor: 2.671

  3 in total
  1 in total

1.  Study on the properties of mud films derived from naturally weathered red-bed soil under pressureless conditions.

Authors:  Yi Gao; Zhen Liu; Cuiying Zhou
Journal:  PLoS One       Date:  2022-10-10       Impact factor: 3.752

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.