Literature DB >> 2146322

Gating of the so-called 'lymphocytic' cell population for the quantification of natural killer cells (CD16+) by flow cytometry causes loss of CD16 positive cells.

A M Lagaay1, C B Bosman, M Van der Keur, G J Ligthart, H R Schuit, H J Tanke, W Hijmans.   

Abstract

Natural killer cells can phenotypically be identified as CD16 positive with a specific monoclonal antibody (B73.1 = Leu-11c) by either immunofluorescence microscopy or by flow cytometry. The standard procedure in flow cytometry is to set a window or gate around the so called lymphocytic population, based on scatter characteristics. In this paper we demonstrate that a substantial part of the NK cell population is situated outside this gate in the total mononuclear cell population. We therefore recommend that the number of CD16+ cells is determined in the total mononuclear cell population. However, in the total mononuclear cell population, a group of dimly CD16 positive cells, probably monocytes, interferes with a clear separation of cells with a positive and negative fluorescence. We describe two methods to overcome this problem.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2146322     DOI: 10.1016/0022-1759(90)90364-2

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  4 in total

Review 1.  Diagnostic pathology and laboratory medicine in the age of "omics": a paper from the 2006 William Beaumont Hospital Symposium on Molecular Pathology.

Authors:  William G Finn
Journal:  J Mol Diagn       Date:  2007-07-25       Impact factor: 5.568

2.  Flow cytometric analysis of ovine peripheral blood lymphocytes.

Authors:  H E Smith; R M Jacobs; C Smith
Journal:  Can J Vet Res       Date:  1994-04       Impact factor: 1.310

3.  Effect of SIVmac infection on plasmacytoid and CD1c+ myeloid dendritic cells in cynomolgus macaques.

Authors:  Benoît Malleret; Ingrid Karlsson; Benjamin Manéglier; Patricia Brochard; Benoît Delache; Thibault Andrieu; Michaela Muller-Trutwin; Tim Beaumont; Joseph M McCune; Jacques Banchereau; Roger Le Grand; Bruno Vaslin
Journal:  Immunology       Date:  2008-01-24       Impact factor: 7.397

4.  Flow cytometric analysis of peripheral blood lymphocyte subset light scatter characteristics as a means of monitoring the development of rat small bowel allograft rejection.

Authors:  G A Webster; M J Bowles; M S Karim; R F Wood; A G Pockley
Journal:  Clin Exp Immunol       Date:  1995-06       Impact factor: 4.330

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.