| Literature DB >> 21461232 |
Srinivasa B Rao1, Ramesh Chowdhary.
Abstract
Dental casting alloys are widely used in contact with oral tissue for many years now. With the development of new dental alloys over the past 15 years, many questions remain unanswered about their biologic safety. Concepts and current issues concerning the response to the biologic effects of dental casting alloys are presented. In this paper, samples of three commercially available nickel-chrome (Ni-cr) casting alloys (Dentaurum, Bego, Sankin) were taken to assess their corrosion behavior, using potentiodynamic polarization method (electrochemical method) with fusayama artificial saliva as an electrolyte medium to check for their biocompatibility. The parameters for corrosion rate and corrosion resistance were obtained from computer-controlled corrosion schematic instrument, namely, potentiostat through corrosion software (power CV). The results obtained were analyzed by classic Tafel analysis. Statistical analysis was done by Student's t-test and ANOVA test. It was concluded that Dentarum and Bego showed satisfactory corrosive behavior, with exception of Sankin which depicted higher corrosion rate and least resistance to corrosion. Thus, the selection of an alloy should be made on the basis of corrosion resistance and biologic data from dental manufactures.Entities:
Year: 2011 PMID: 21461232 PMCID: PMC3062075 DOI: 10.1155/2011/397029
Source DB: PubMed Journal: Int J Dent ISSN: 1687-8728
Details of the metal alloys used.
| Base metal alloy | Manufacturing company | Product name | Composition |
|---|---|---|---|
| Nickel chromium | Dentaurum | Remanium CS | Ni-61 wt% |
| Cr-26 wt% | |||
| Mo-11 wt% | |||
| Si-1.5 | |||
| Fe | |||
| Ce | |||
| A1 | |||
| Co < 1 | |||
|
| |||
| Nickel chromium | Bego | Wiron 99 | Ni-65 |
| Cr-22.5 | |||
| Mo-9.5 | |||
| No:1 | |||
| Si −1 | |||
| Fe-0.5 | |||
| Ce-0.5 | |||
| C:0.02 | |||
|
| |||
| Nickel chromium | Dentsply Sankin | CB Soft | Ni-72.8 |
| Cr-4.9 | |||
| Cu-12.3 | |||
| Other −10% | |||
Composition of fusayama artificial saliva solution.
| 0.96 grams (gms) | Kcl Potassium chloride |
| 0.674 gms | Nacl sodium chloride |
| 0.0405 gms | Mgcl2·6H2O magnesium chloride |
| 0.117 gms | Cacl2·2H2O calcium chloride |
| 0.091 gms | K2HPO4 potassium di hydrogen phosphate |
| 0.11 gms | methyl parahydroxybenzoate |
| 8.0 gm | 70% sorbitol |
Mean values for corrosion rate (MPY).
| Alloys | 10th day | 20th day | 30th day |
|---|---|---|---|
| Dentaurum Remanium (CS) | 17.0130506 | 47.1277852 | 16.61719 |
| Bego (Wiron 99) | 51.726802 | 44.1613956 | 82.0454818 |
| Sankin (CB Soft) | 26.8303936 | 61.8402746 | 293.692578 |
Mean values for corrosion potential E (mV).
| 10th day | 20th day | 30th day | |
|---|---|---|---|
| Dentaurum Remanium (CS) | 431.18 | 441.78 | 492.58 |
| Bego (Wiron 99) | 470.86 | 493.28 | 744.08 |
| Sankin (CB Soft) | 567.58 | 587.32 | 740.58 |
Mean values of corrosion current density I (A).
| 10th day | 20th day | 30th day | |
|---|---|---|---|
| Dentaurum Remanium (CS) | 3.51 | 3.736 | 3.092 |
| Bego (Wiron 99) | 4.95 | 3.818 | 4.622 |
| Sankin (CB Soft) | 5.998 | 6.554 | 3.376 |
Mean values for corrosion resistance (K cm−2).
| 10th day | 20th day | 30th day | |
|---|---|---|---|
| Dentaurum Remanium (CS) | 20.38 | 14.34 | 18.18 |
| Bego (Wiron 99) | 21.98 | 12.33 | 16.77 |
| Sankin (CB Soft) | 15.95 | 15.95 | 12.12 |
Figure 1Comparison of corrosion rate (t-values) of casting alloys at various intervals of time.
Figure 2Comparison of corrosion rate of nickel-chrome casting alloys at various intervals of time.