PURPOSE: To assess the potential reduction in breast dose for young girls with Hodgkin's lymphoma (HL) treated with breast-sparing proton therapy (BS-PT) as compared with three-dimensional conformal involved-field photon radiotherapy (3D-CRT). METHODS AND MATERIALS: The Clarian Health Cancer Registry was queried for female pediatric patients with the diagnosis of HL who received radiotherapy at the Indiana University Simon Cancer Center during 2006-2009. The original CT simulation images were obtained, and 3D-CRT and BS-PT plans delivering 21 Gy or cobalt gray equivalent (CGE) in 14 fractions were created for each patient. Dose-volume histogram data were collected for both 3D-CRT and BS-PT plans and compared by paired t test for correlated samples. RESULTS: The cancer registry provided 10 female patients with Ann Arbor Stage II HL, aged 10-18 years at the time of treatment. Both mean and maximum breast dose were significantly less with BS-PT compared with 3D-CRT: 0.95 CGE vs. 4.70 Gy (p < 0.001) and 21.07 CGE vs. 23.11 Gy (p < 0.001), respectively. The volume of breast receiving 1.0 Gy/CGE and 5.0 Gy/CGE was also significantly less with BS-PT, 194 cm(3) and 93 cm(3), respectively, compared with 790 cm(3) and 360 cm(3) with 3D-CRT (p = 0.009, 0.013). CONCLUSION: Breast-sparing proton therapy has the potential to reduce unnecessary breast dose in young girls with HL by as much as 80% relative to involved-field 3D-CRT.
PURPOSE: To assess the potential reduction in breast dose for young girls with Hodgkin's lymphoma (HL) treated with breast-sparing proton therapy (BS-PT) as compared with three-dimensional conformal involved-field photon radiotherapy (3D-CRT). METHODS AND MATERIALS: The Clarian Health Cancer Registry was queried for female pediatric patients with the diagnosis of HL who received radiotherapy at the Indiana University Simon Cancer Center during 2006-2009. The original CT simulation images were obtained, and 3D-CRT and BS-PT plans delivering 21 Gy or cobalt gray equivalent (CGE) in 14 fractions were created for each patient. Dose-volume histogram data were collected for both 3D-CRT and BS-PT plans and compared by paired t test for correlated samples. RESULTS: The cancer registry provided 10 female patients with Ann Arbor Stage II HL, aged 10-18 years at the time of treatment. Both mean and maximum breast dose were significantly less with BS-PT compared with 3D-CRT: 0.95 CGE vs. 4.70 Gy (p < 0.001) and 21.07 CGE vs. 23.11 Gy (p < 0.001), respectively. The volume of breast receiving 1.0 Gy/CGE and 5.0 Gy/CGE was also significantly less with BS-PT, 194 cm(3) and 93 cm(3), respectively, compared with 790 cm(3) and 360 cm(3) with 3D-CRT (p = 0.009, 0.013). CONCLUSION: Breast-sparing proton therapy has the potential to reduce unnecessary breast dose in young girls with HL by as much as 80% relative to involved-field 3D-CRT.
Authors: B Knäusl; C Lütgendorf-Caucig; J Hopfgartner; K Dieckmann; L Kurch; T Pelz; R Pötter; D Georg Journal: Strahlenther Onkol Date: 2012-11-18 Impact factor: 3.621
Authors: Frank Lohr; Dietmar Georg; Luca Cozzi; Hans Theodor Eich; Damien C Weber; Julia Koeck; Barbara Knäusl; Karin Dieckmann; Yasser Abo-Madyan; Christian Fiandra; Rolf-Peter Mueller; Andreas Engert; Umberto Ricardi Journal: Strahlenther Onkol Date: 2014-09-11 Impact factor: 3.621
Authors: Bouthaina Shbib Dabaja; Bradford S Hoppe; John P Plastaras; Wayne Newhauser; Katerina Rosolova; Stella Flampouri; Radhe Mohan; N George Mikhaeel; Youlia Kirova; Lena Specht; Joachim Yahalom Journal: Blood Date: 2018-08-14 Impact factor: 22.113
Authors: Laura Ann Rechner; Maja Vestmø Maraldo; Ivan Richter Vogelius; Xiaorong Ronald Zhu; Bouthaina Shbib Dabaja; Nils Patrik Brodin; Peter Meidahl Petersen; Lena Specht; Marianne Camille Aznar Journal: Radiother Oncol Date: 2017-08-30 Impact factor: 6.280