Literature DB >> 21459430

Unrestricted randomised use of two new generation drug-eluting coronary stents: 2-year patient-related versus stent-related outcomes from the RESOLUTE All Comers trial.

Sigmund Silber1, Stephan Windecker, Pascal Vranckx, Patrick W Serruys.   

Abstract

BACKGROUND: In the RESOLUTE All Comers trial, the Resolute zotarolimus-eluting stent was non-inferior to the Xience V everolimus-eluting stent for the primary stent-related endpoint of target lesion failure (cardiac death, target vessel myocardial infarction, and ischaemia-driven target lesion revascularisation) at 1 year. However, data for long-term safety and efficacy from randomised studies of new generation drug-eluting coronary stents in patients treated in routine clinical practice are scarce. We report the prespecified 2-year clinical outcomes from the RESOLUTE All Comers trial.
METHODS: In 2008, patients with at least one coronary lesion 2.25-4.0 mm in diameter, with greater than 50% stenosis, were randomly assigned to a Resolute zotarolimus-eluting stent or a Xience V everolimus-eluting stent at 17 centres in Europe and Israel. Randomisation was by an interactive voice response system stratified by centre. Study investigators were not masked to treatment allocation; but those who did data management and analysis, and patients were masked. There were no restrictions as to the number of vessels or lesions treated, or the number of stents implanted. We assessed prespecified safety and efficacy outcomes at 2 years with specific focus on patient-related composite (all death, all myocardial infarction, all revascularisation) and stent-related composite outcomes. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00617084.
FINDINGS: 1140 patients were assigned to the zotarolimus-eluting stent and 1152 to the everolimus-eluting stent; 1121 and 1128 patients, respectively, completed 2-year follow-up. The patient-related outcome (231 [20.6%] zotarolimus vs 231 [20.5%] everolimus; difference 0.1%, 95% CI-3.2 to 3.5; p=0.958) and stent-related outcome (126 [11.2%] vs 121 [10.7%]; difference 0.5%, -2.1 to 3.1; p=0.736) did not differ between groups, although rates of the stent-related outcome were substantially lower than were those for the patient-related outcome. Three patients in each group (0.3%) had very late (after 1 year) stent thrombosis.
INTERPRETATION: Similar safety and efficacy outcomes were sustained between two new generation drug-eluting stents at 2-year follow-up. The greater number of patient-related than stent-related events in patients with complex clinical and lesion characteristics emphasises that during long-term follow-up, the optimisation of secondary prevention is at least as important as the selection of which new generation drug-eluting stent to implant in a specific lesion. FUNDING: Medtronic (USA).
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21459430     DOI: 10.1016/S0140-6736(11)60395-4

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  35 in total

Review 1.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

Review 2.  Late stent thrombosis: the last remaining obstacle in coronary interventional therapy.

Authors:  Piera Capranzano; George Dangas
Journal:  Curr Cardiol Rep       Date:  2012-08       Impact factor: 2.931

3.  Interventional cardiology. The importance of patient-related factors on PCI outcomes.

Authors:  Joana Osório
Journal:  Nat Rev Cardiol       Date:  2011-05-03       Impact factor: 32.419

4.  Hotline update of clinical trials and registries presented at the 77th spring meeting of the German Society of Cardiology 2011.

Authors:  J M Sinning; K Walenta; N Werner; M Böhm
Journal:  Clin Res Cardiol       Date:  2011-06-09       Impact factor: 5.460

5.  STENTING STRATEGY AND FOLLOW-UP RESULTS OF MULTI-CENTER REGISTRY IN FUKUSHIMA CITY FOR LEFT MAIN CORONARY ARTERY DISEASE: BARE METAL STENT VERSUS DRUG-ELUTING STENT.

Authors:  Kazuhiko Nakazato; Hiroyuki Mizukami; Hideki Ohtake; Nobuo Sakamoto; Takayoshi Yamaki; Osamu Yamaguchi; Hiroyuki Kunii; Takayuki Ohwada; Yasuchika Takeishi
Journal:  Fukushima J Med Sci       Date:  2015-07-02

6.  Risk factors for clinical events at 1-year follow-up after drug-eluting stent implantation: results from the prospective multicenter German DES.DE registry.

Authors:  I Akin; C A Nienaber; G Richardt; R Tölg; M Hochadel; S Schneider; J Senges; U Tebbe; U Zeymer; G Sabin; K-H Kuck; M W Bergmann
Journal:  Clin Res Cardiol       Date:  2014-01-28       Impact factor: 5.460

7.  Risk stratification in acute coronary syndromes.

Authors:  Gabriele Pesarini; Francesco Santini; Giulia Geremia; Carlo Zivelonghi; Flavio Ribichini
Journal:  J Cardiovasc Transl Res       Date:  2011-12-02       Impact factor: 4.132

8.  Under-reporting of venous and arterial thrombotic events in randomized clinical trials: a meta-analysis.

Authors:  Danka J F Stuijver; Erica Romualdi; Bregje van Zaane; Leon Bax; Harry R Büller; Victor E A Gerdes; Alessandro Squizzato
Journal:  Intern Emerg Med       Date:  2014-12-13       Impact factor: 3.397

9.  Stent thrombosis is a major concern in clinical practice: A single Saudi center experience.

Authors:  Mohammed A Balghith; Ali M Alghamdi; Kamal M Ayoub; Amir A Saleh; Mohammed S Aziz; Monirah Algahtany; Fatima Almasood; Gaida M Albargy
Journal:  J Saudi Heart Assoc       Date:  2013-10

Review 10.  Coronary artery revascularization in patients with diabetes mellitus.

Authors:  Ehrin J Armstrong; John C Rutledge; Jason H Rogers
Journal:  Circulation       Date:  2013-10-08       Impact factor: 29.690

View more