Literature DB >> 21459053

Quantitative liquid chromatographic and tandem mass spectrometric determination of vitamin D3 in human serum with derivatization: a comparison of in-tube LLE, 96-well plate LLE and in-tip SPME.

W Xie1, C M Chavez-Eng, W Fang, M L Constanzer, B K Matuszewski, W M Mullett, J Pawliszyn.   

Abstract

Sensitive and selective methods based on high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection were developed for the determination of vitamin D(3) in human serum. Derivatization of vitamin D(3) and its stable isotope labeled internal standard provided highly sensitive quantification and selective detection from endogenous compounds. Samples were prepared using the in-tube liquid-liquid extraction (LLE), 96-well plate LLE, and in-tip solid phase micro-extraction (SPME) in 96-well format. In all methods, the MS/MS detection was performed using Applied Biosystems-Sciex API 3000 tandem mass spectrometers interfaced with a heated nebulizer probe and operated in the positive ionization mode. Both tube and plate LLE methods achieved a lower limit of quantitation (LLOQ) of 0.5 ng/mL when 1.0 and 0.4 mL of human serum was processed, respectively, and were validated in the concentration range of 0.5-25 ng/mL; while for the in-tip SPME method, LLOQ was 5 ng/mL with only 0.1 mL of human serum required. Comparisons were made among three different methods, including precision and accuracy, sample throughput, recovery and matrix effects.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21459053     DOI: 10.1016/j.jchromb.2011.03.018

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Development and comparison of three liquid chromatography-atmospheric pressure chemical ionization/mass spectrometry methods for determining vitamin D metabolites in human serum.

Authors:  Mary Bedner; Karen W Phinney
Journal:  J Chromatogr A       Date:  2012-04-05       Impact factor: 4.759

Review 2.  Vitamin D and metabolites measurement by tandem mass spectrometry.

Authors:  Johannes M W van den Ouweland; Michael Vogeser; Silvia Bächer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

3.  A Small Footprint and Robust Interface for Solid Phase Microextraction and Mass Spectrometry Based on Vibrating Sharp-Edge Spray Ionization.

Authors:  Jing Wang; Chong Li; Peng Li
Journal:  J Am Soc Mass Spectrom       Date:  2022-01-18       Impact factor: 3.262

4.  Comparison of two online extraction systems and development of the online SPE-HPLC-DAD method to simultaneously determine ten β-amino alcohol drugs in plasma.

Authors:  Man Wang; Lei Liu; Zheng Yin; Yaxin Lu
Journal:  RSC Adv       Date:  2018-02-05       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.