Literature DB >> 21458762

Variation in pediatric head CT imaging protocols in Washington state.

Kalpana M Kanal1, Monica S Vavilala, Colin Raelson, Abhishek Mohan, Wendy Cohen, Jeffrey Jarvik, Frederick P Rivara, Brent K Stewart.   

Abstract

PURPOSE: To examine variation in pediatric trauma head CT imaging protocols in Washington state.
METHODS: A web-based survey was sent to trauma-designated hospitals in Washington state. Respondents were queried about pediatric head trauma volumes, type of CT scanners, and technical information about the CT imaging protocols. Variation in pediatric trauma volumes, CT dose reduction strategies, and effective dose by trauma center levels was examined. Mean head effective dose and organ dose for a female baby were estimated.
RESULTS: We achieved a 76% overall response rate. Of the 2,215 children who received head CT scans, 36.3% (n=805) received head CT imaging at level 4 trauma center facilities, followed by level 1 trauma center (31.4%; n=695), level 3 trauma center (19.7%; n=436), level 2 trauma center (12%; n=267), and Level 5 (0.5%; n=12) facilities. Most responding trauma center facilities (44/47) reported having a pediatric specific imaging head CT protocols. However, compared to levels 1 and 2 trauma centers together, a greater proportion of levels 3, 4 & 5 trauma center facilities collectively lacked dose reduction strategies (0% vs. 25-57%), tended to have higher mAs (169 ± 113 vs. 110 ± 36), and were later adopters of dose reduction strategies on the CT scanners. There was more than a 10-fold variation in estimated median effective dose for a baby within level 4 trauma center facilities (3.5 ± 0.84 mSv, range 0.60 to 9.60 mSv). DISCUSSION: There is both within and between trauma center level variation in pediatric head CT imaging protocols and radiation dose in Washington state.
Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21458762     DOI: 10.1016/j.jacr.2010.11.005

Source DB:  PubMed          Journal:  J Am Coll Radiol        ISSN: 1546-1440            Impact factor:   5.532


  7 in total

1.  The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

Authors:  G A Vorona; G Zuccoli; T Sutcavage; B L Clayton; R C Ceschin; A Panigrahy
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-24       Impact factor: 3.825

Review 2.  Diagnostic yield of computed tomography scan for pediatric hearing loss: a systematic review.

Authors:  Jenny X Chen; Bart Kachniarz; Jennifer J Shin
Journal:  Otolaryngol Head Neck Surg       Date:  2014-09-03       Impact factor: 3.497

Review 3.  Pitfalls in the interpretation of pediatric head CTs: what the emergency radiologist needs to know.

Authors:  Hannah Hodges; Katherine N Epstein; Michele Retrouvey; Sherry S Wang; Allyson A Richards; Dustin Lima; Jonathan W Revels
Journal:  Emerg Radiol       Date:  2022-04-08

4.  Cumulative medical radiation exposure throughout staged palliation of single ventricle congenital heart disease.

Authors:  Tacy E Downing; Alicia McDonnell; Xiaowei Zhu; Yoav Dori; Matthew J Gillespie; Jonathan J Rome; Andrew C Glatz
Journal:  Pediatr Cardiol       Date:  2014-08-06       Impact factor: 1.655

5.  Hospital-level factors associated with use of pediatric radiation dose-reduction protocols for head CT: results from a national survey.

Authors:  Janessa M Graves; Kalpana M Kanal; Monica S Vavilala; Kimberly E Applegate; Jeffrey G Jarvik; Frederick P Rivara
Journal:  J Am Coll Radiol       Date:  2014-07       Impact factor: 5.532

6.  Dose reduction efforts for pediatric head CT imaging in Washington State trauma centers: follow-up survey results.

Authors:  Janessa M Graves; Kalpana M Kanal; Frederick P Rivara; Jeffrey G Jarvik; Monica S Vavilala
Journal:  J Am Coll Radiol       Date:  2013-12-20       Impact factor: 5.532

7.  Variability in image quality and radiation dose within and across 97 medical facilities.

Authors:  Taylor B Smith; Shuaiqi Zhang; Alaattin Erkanli; Donald Frush; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.