Literature DB >> 21457408

The use of the new ReFacto AF Laboratory Standard allows reliable measurement of FVIII:C levels in ReFacto AF mock plasma samples by a one-stage clotting assay.

C Pouplard1, C Caron, M F Aillaud, C Ternisien, C Desconclois, A Dubanchet, F Sobas.   

Abstract

Factor VIII coagulant (FVIII:C) levels measured in patients receiving ReFacto® (B-domain-deleted recombinant FVIII) using chromogenic substrate assay (CSA) and one-stage clotting assay (OSA) have frequently shown discrepancies, and the use of the ReFacto Laboratory Standard (RLS) has therefore been recommended to minimize these differences. The potency of ReFacto AF®, the albumin-free successor of ReFacto®, is determined using CSA for the titration of vials, and a new standard (RLS-AF) was developed to measure its biological efficacy using OSA. This multicentre study therefore evaluated the efficacy of this new RLS in minimizing differences between OSA and CSA when measuring FVIII:C levels in plasma. Mock plasma samples were prepared by diluting ReFacto AF® in FVIII-deficient plasma to obtain four concentrations ranging from 15 to 90 IU dL⁻¹ . FVIII:C levels were then measured in six laboratories on four separate days using three different procedures, i.e. OSA with a plasma standard (PS) as reference, OSA with RLS-AF and CSA with PS. The inter-centre standard deviation ranged from 1.4 to 5.5 IU dL⁻¹. However, FVIII:C levels measured with OSA were closer to the expected values when RLS-AF was used. In addition, the uncertainty of measurement, reflecting the inter-method discrepancy was greatly reduced when RLS-AF was employed in OSA (15%) in place of PS (33%). This study demonstrates that the OSA performed with RLS-AF to establish calibration curves provides a valuable alternative to CSA to measure FVIII:C in ReFacto-AF-treated patients.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21457408     DOI: 10.1111/j.1365-2516.2011.02523.x

Source DB:  PubMed          Journal:  Haemophilia        ISSN: 1351-8216            Impact factor:   4.287


  2 in total

Review 1.  Clinical utility and impact of the use of the chromogenic vs one-stage factor activity assays in haemophilia A and B.

Authors:  Richard A Marlar; Karin Strandberg; Midori Shima; Dorothy M Adcock
Journal:  Eur J Haematol       Date:  2019-11-13       Impact factor: 2.997

2.  Comparative field study evaluating the activity of recombinant factor VIII Fc fusion protein in plasma samples at clinical haemostasis laboratories.

Authors:  J M Sommer; N Moore; B McGuffie-Valentine; S Bardan; Y Buyue; G D Kamphaus; B A Konkle; G F Pierce
Journal:  Haemophilia       Date:  2013-11-22       Impact factor: 4.287

  2 in total