Literature DB >> 21455793

Performance evaluation of five types of Ag/AgCl bio-electrodes for cerebral electrical impedance tomography.

Shiwei Xu1, Meng Dai, Canhua Xu, Chaoshuang Chen, Mengxing Tang, Xuetao Shi, Xiuzhen Dong.   

Abstract

Electrical impedance tomography (EIT) is an emerging medical imaging technique, which has already been investigated in several clinical applications due to its low-cost, non-invasiveness, non-radioactivity, high temporal resolution, and great sensitivity to impedance changes. One potential use of EIT is to perform long-term continuous imaging monitoring of brain for patients who suffer from severe cerebral diseases. However, this application requires a demanding performance of electrodes because of the characteristics of cerebral EIT measurements. Although Ag/AgCl bio-electrodes are widely used for clinical practices or EIT research at the moment, influences of different types of Ag/AgCl electrodes on cerebral EIT measurements have not been investigated. In this study, five common types of Ag/AgCl bio-electrodes were put into comparison by measuring the forearm and the brain of 10 healthy adult volunteers and evaluating those data in frequency or time domain in terms of contact impedance, uniformity, signal-to-noise ratio, and stability. Results show that Ag/AgCl powder electrode has an overall best performance with as low contact impedance as commercial ECG electrodes (p > 0.05), high SNR (60.3 ± 4.5 dB), better uniformity (coefficient of correlation 0.95 ± 0.03), and greater stability (slope 0.68 ± 0.03). After further improvement in design and instrumentation, Ag/AgCl powder electrode is likely to become the optimal choice for cerebral EIT measurements and provide feasible technical support for further research or application in cerebral EIT.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21455793     DOI: 10.1007/s10439-011-0302-9

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  10 in total

1.  Different displacement of bioimpedance vector due to Ag/AgCl electrode effect.

Authors:  L Nescolarde; H Lukaski; A De Lorenzo; B de-Mateo-Silleras; M P Redondo-Del-Río; M A Camina-Martín
Journal:  Eur J Clin Nutr       Date:  2016-07-06       Impact factor: 4.016

2.  Preparation and characterization of a novel sprayable hydrogel for skin preparation to record ECG and other biopotentials.

Authors:  Sunil Tej Boppudi; Suliman Belal; Sitaramanjaneya Reddy Guntur
Journal:  Biomed Eng Lett       Date:  2020-07-29

3.  Multi-frequency electrical impedance tomography and neuroimaging data in stroke patients.

Authors:  Nir Goren; James Avery; Thomas Dowrick; Eleanor Mackle; Anna Witkowska-Wrobel; David Werring; David Holder
Journal:  Sci Data       Date:  2018-07-03       Impact factor: 6.444

4.  Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring.

Authors:  Lei Ren; Qing Jiang; Keyun Chen; Zhipeng Chen; Chengfeng Pan; Lelun Jiang
Journal:  Sensors (Basel)       Date:  2016-06-17       Impact factor: 3.576

5.  A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System.

Authors:  James Avery; Thomas Dowrick; Mayo Faulkner; Nir Goren; David Holder
Journal:  Sensors (Basel)       Date:  2017-01-31       Impact factor: 3.576

6.  Fabrication of Composite Microneedle Array Electrode for Temperature and Bio-Signal Monitoring.

Authors:  Yiwei Sun; Lei Ren; Lelun Jiang; Yong Tang; Bin Liu
Journal:  Sensors (Basel)       Date:  2018-04-13       Impact factor: 3.576

Review 7.  Advances in electrical impedance tomography-based brain imaging.

Authors:  Xi-Yang Ke; Wei Hou; Qi Huang; Xue Hou; Xue-Ying Bao; Wei-Xuan Kong; Cheng-Xiang Li; Yu-Qi Qiu; Si-Yi Hu; Li-Hua Dong
Journal:  Mil Med Res       Date:  2022-02-28

8.  In vivo imaging of twist drill drainage for subdural hematoma: a clinical feasibility study on electrical impedance tomography for measuring intracranial bleeding in humans.

Authors:  Meng Dai; Bing Li; Shijie Hu; Canhua Xu; Bin Yang; Jianbo Li; Feng Fu; Zhou Fei; Xiuzhen Dong
Journal:  PLoS One       Date:  2013-01-25       Impact factor: 3.240

9.  Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method.

Authors:  Keyun Chen; Lei Ren; Zhipeng Chen; Chengfeng Pan; Wei Zhou; Lelun Jiang
Journal:  Sensors (Basel)       Date:  2016-09-20       Impact factor: 3.576

10.  A Low Contact Impedance Medical Flexible Electrode Based on a Pyramid Array Micro-Structure.

Authors:  Song Wang; Jin Yan; Canlin Zhu; Jialin Yao; Qiusheng Liu; Xing Yang
Journal:  Micromachines (Basel)       Date:  2020-01-01       Impact factor: 2.891

  10 in total