Experimental investigations into visual and electronic tooth color measurement.

Anja Ratzmann1, Anja Treichel, Gabriele Langforth, Tomasz Gedrange, Alexander Welk.   

Abstract

OBJECTIVE: The present study aimed to examine the validity of the visual color assessment and an electronic tooth color measurement system by means of Shade Inspector™ in comparison with a gold standard. Additionally, reproducibility of electronic measurements was demonstrated by means of two reference systems.
MATERIAL AND METHODS: Ceramic specimens of two thicknesses (h=1.6 mm, h=2.6 mm) were used. Three experienced dental technicians using the VITAPAN Classical(®) color scale carried out all visual tests. Validity of the visual assessment and the electronic measurements was confirmed separately for both thicknesses by means of lightness and hue of the VITAPAN Classical(®) color scale. Reproducibility of electronic measurements was confirmed by means of the VITAPAN Classical(®) and 3D-Master(®). The 3D-Master(®) data were calculated according to lightness, hue and chroma. Intraclass correlation coefficient (ICC) was used in assessing validity/reproducibility for lightness and chroma, Kappa statistics were used for hue. A level ≥0.75 was pre-established for ICC and ≥0.60 for the Kappa index. RESULTS OF VISUAL COLOR ASSESSMENT: Validity for lightness was good for both thicknesses; agreement rates for hue were inconsistent. ELECTRONIC MEASUREMENT: Validity for lightness was fair to good, hue values were below 0.60. Reproducibility of lightness was good to very good for both reference systems. Hue values (VITAPAN Classical(®)) for 1.6 mm test specimens were upside, for 2.6 mm below 0.60, Kappa values for 3D-Master(®) were ≥0.60 for all measurements, reproducibility of chroma was very good.
CONCLUSION: Validity was better for visual than for electronic color assessment. Reproducibility of the electronic device by means of the Shade Inspector™ was given for the VITAPAN Classical(®) and 3D-Master(®) systems.

Entities:  

Mesh:

Year:  2011        PMID: 21453129     DOI: 10.1515/BMT.2011.008

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  3 in total

1.  Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems.

Authors:  Vidhya Parameswaran; S Anilkumar; S Lylajam; C Rajesh; Vivek Narayan
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

2.  Assessment of perceptibility and acceptability of color variations between matched teeth among trainee dentist and lay person.

Authors:  A S Ramesh; Aruna Sharma; K Rijesh; R Prakash; Lakshmi Devi; Edilbert Raja
Journal:  J Pharm Bioallied Sci       Date:  2015-08

3.  Assessing the effect of multibracket appliance treatment on tooth color by using electronic measurement.

Authors:  Anja Ratzmann; Christan Schwahn; Anja Treichel; Andreas Faltermeier; Alexander Welk
Journal:  Head Face Med       Date:  2018-10-22       Impact factor: 2.151

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.