Image formation in CARS microscopy: effect of the Gouy phase shift.

K I Popov1, A F Pegoraro, A Stolow, L Ramunno.   

Abstract

Image formation in Coherent Anti-Stokes Raman Scattering (CARS) microscopy of sub-wavelength objects is investigated via a combined experimental, numerical and theoretical study. We consider a resonant spherical object in the presence of a nonresonant background, using tightly focused laser pulses. When the object is translated along the laser propagation axis, we find the CARS signal to be asymmetric about the laser focal plane. When the object is located before the focus, there is a distinct shadow within the image, whereas the brightest signal is obtained when the object is behind the focus. This behaviour is caused by interference between resonant and nonresonant signals, and the Gouy phase shift is responsible for the observed asymmetry within the image.

Mesh:

Year:  2011        PMID: 21451615     DOI: 10.1364/OE.19.005902

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  5 in total

1.  Direct visualization of the arterial wall water permeability barrier using CARS microscopy.

Authors:  Bertrand M Lucotte; Chloe Powell; Jay R Knutson; Christian A Combs; Daniela Malide; Zu-Xi Yu; Mark Knepper; Keval D Patel; Anna Pielach; Errin Johnson; Lyudmyla Borysova; Kim A Dora; Robert S Balaban
Journal:  Proc Natl Acad Sci U S A       Date:  2017-04-03       Impact factor: 11.205

2.  Stimulated Raman Scattering: From Bulk to Nano.

Authors:  Richard C Prince; Renee R Frontiera; Eric O Potma
Journal:  Chem Rev       Date:  2016-12-14       Impact factor: 60.622

Review 3.  Biomolecular imaging with coherent nonlinear vibrational microscopy.

Authors:  Chao-Yu Chung; Eric O Potma
Journal:  Annu Rev Phys Chem       Date:  2012-12-05       Impact factor: 12.703

4.  Controlling stimulated coherent spectroscopy and microscopy by a position-dependent phase.

Authors:  Chao-Yu Chung; Julie Hsu; Shaul Mukamel; Eric O Potma
Journal:  Phys Rev A       Date:  2013-03-26       Impact factor: 3.140

5.  Imaging skeletal muscle using second harmonic generation and coherent anti-Stokes Raman scattering microscopy.

Authors:  Christian P Pfeffer; Bjorn R Olsen; Feruz Ganikhanov; François Légaré
Journal:  Biomed Opt Express       Date:  2011-04-27       Impact factor: 3.732

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.