Literature DB >> 21450538

An accurate quantitative LC/ESI-MS/MS method for sirolimus in human whole blood.

Nariyasu Mano1, Mayumi Sato, Marina Nozawa, Yotaro Matsumoto, Masaru Mori, Hiroaki Yamaguchi, Junichi Goto, Miki Shimada.   

Abstract

Sirolimus is a widely used immunosuppressant that requires therapeutic drug monitoring (TDM). We optimized a preanalytical procedure that allows for the accurate quantiation of sirolimus in whole blood by LC/ESI-MS/MS with minimal matrix effects. Sirolimus is highly lipophilic, and solvents containing greater than 50% methanol were required to maintain sirolimus recovery. The final pretreatment procedure developed consists of a zinc sulfate protein precipitation, an extraction using octadecyl silyl-silica gel for eliminating water-soluble and hydrophilic compounds, and HybridSPE cartridge treatment to eliminate phospholipids. Using this procedure prior to LC/ESI-MS/MS led to the accurate and reproducible quantitation of sirolimus in human whole blood. The linear range of detection was 0.5-50 ng/mL, a range appropriate for TDM, and the method demonstrated good repeatability and intermediate precision within this quantitative range. In order to investigate the quantitative performance of this method, we compared it to two commercially available sirolimus immunoassays and our previously reported LC/ESI-MS/MS method. The immunoassays gave consistently greater values for the sirolimus concentration, and this may be related to antibody cross-reactivity with sirolimus metabolites and/or other matrix effects. Although our procedure is too long to support real-time TDM for outpatients, it can serve as reference method to assess the performance of other analytical methods that are currently available or may be developed in the future.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21450538     DOI: 10.1016/j.jchromb.2011.03.013

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Application of response surface methodology in development of sirolimus liposomes prepared by thin film hydration technique.

Authors:  Saeed Ghanbarzadeh; Hadi Valizadeh; Parvin Zakeri-Milani
Journal:  Bioimpacts       Date:  2013-04-30

2.  Bioanalytical method validation of rapamycin in ocular matrix by QTRAP LC-MS/MS: application to rabbit anterior tissue distribution by topical administration of rapamycin nanomicellar formulation.

Authors:  Ravinder Earla; Kishore Cholkar; Sriram Gunda; Rajya Lakshmi Earla; Ashim K Mitra
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2012-10-03       Impact factor: 3.205

3.  Development and Validation of a Bioanalytical LC-MS/MS Method for Simultaneous Determination of Sirolimus in Porcine Whole Blood and Lung Tissue and Pharmacokinetic Application with Coronary Stents.

Authors:  Thi-Thao-Linh Nguyen; Van-An Duong; Dang-Khoa Vo; Jeongae Jo; Han-Joo Maeng
Journal:  Molecules       Date:  2021-01-15       Impact factor: 4.411

4.  Comparison of LC-MS/MS and EMIT methods for the precise determination of blood sirolimus in children with vascular anomalies.

Authors:  Yue-Tao Zhao; Hao-Ran Dai; Yue Li; Yuan-Yuan Zhang; Hong-Li Guo; Xuan-Sheng Ding; Ya-Hui Hu; Feng Chen
Journal:  Front Pharmacol       Date:  2022-09-06       Impact factor: 5.988

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.