Literature DB >> 21449909

Three-dimensional finite element analysis of stress distribution in peri-implant bone with relined dentures and different heights of healing caps.

M B F Dos Santos1, J P Da Silva Neto, R L X Consani, M F Mesquita.   

Abstract

The purpose of this study was to evaluate the influence of height of healing caps and the use of soft liner materials on the stress distribution in peri-implant bone during masticatory function in conventional complete dentures during the healing period by using finite element analysis. Three-dimensional models of a severely resorbed mandible with two recently placed implants in the anterior region were created and divided into the following situations: (i) submerged implants, (ii) healing cap at gingival level and (iii) 1·5-mm supragingival. All these situations were also analysed for a conventional complete denture and a denture relined with a 3-mm-thick layer of soft liner material. The models were exported to mechanical simulation software that presented two simulations, one with load in the inferior right canine (35 N) and the other in the inferior right first molar (50 N). Data were evaluated using Maximum Principal Stress provided by the software. All models showed a stress concentration in the cortical bone corresponding to the cervical part of the implant. The simulations with non-submerged implants showed higher values of stress concentration than those that were submerged. Likewise, soft liner materials presented better results than when the denture base was not relined. The height of the healing caps seems to have a direct influence on the stress distribution in the peri-implant bone during the healing period. Considering the values obtained in this study, the use of soft liners with submerged implants seems to be the most suitable method to use during the period of osseointegration.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21449909     DOI: 10.1111/j.1365-2842.2011.02217.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  2 in total

1.  Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading.

Authors:  Mateus Bertolini Fernandes Dos Santos; Bruno Massucato Zen; Atais Bacchi
Journal:  Med Biol Eng Comput       Date:  2015-12-11       Impact factor: 2.602

2.  Investigation of dental elastomers as oral mucosa simulant materials.

Authors:  Joanne Jung Eun Choi; Shiyao Chen; John Neil Waddell
Journal:  Clin Exp Dent Res       Date:  2021-01-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.