Literature DB >> 21449586

Hemocompatibility of poly(vinylidene fluoride) membrane grafted with network-like and brush-like antifouling layer controlled via plasma-induced surface PEGylation.

Yung Chang1, Yu-Ju Shih, Chao-Yin Ko, Jheng-Fong Jhong, Ying-Ling Liu, Ta-Chin Wei.   

Abstract

In this work, the hemocompatibility of PEGylated poly(vinylidene fluoride) (PVDF) microporous membranes with varying grafting coverage and structures via plasma-induced surface PEGylation was studied. Network-like and brush-like PEGylated layers on PVDF membrane surfaces were achieved by low-pressure and atmospheric plasma treatment. The chemical composition, physical morphology, grafting structure, surface hydrophilicity, and hydration capability of prepared membranes were determined to illustrate the correlations between grafting qualities and hemocompatibility of PEGylated PVDF membranes in contact with human blood. Plasma protein adsorption onto different PEGylated PVDF membranes from single-protein solutions and the complex medium of 100% human plasma were measured by enzyme-linked immunosorbent assay (ELISA) with monoclonal antibodies. Hemocompatibility of the PEGylated membranes was evaluated by the antifouling property of platelet adhesion observed by scanning electron microscopy (SEM) and the anticoagulant activity of the blood coagulant determined by testing plasma-clotting time. The control of grafting structures of PEGylated layers highly regulates the PVDF membrane to resist the adsorption of plasma proteins, the adhesion of platelets, and the coagulation of human plasma. It was found that PVDF membranes grafted with brush-like PEGylated layers presented higher hydration capability with binding water molecules than with network-like PEGylated layers to improve the hemocompatible character of plasma protein and blood platelet resistance in human blood. This work suggests that the hemocompatible nature of grafted PEGylated polymers by controlling grafting structures gives them great potential in the molecular design of antithrombogenic membranes for use in human blood.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21449586     DOI: 10.1021/la1048369

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  5 in total

1.  Anti-platelet and tissue engineering approaches to biomaterial blood compatibilization: how well have these been translated into the clinic?

Authors:  Scott Alexander Irvine; Xia Yun; Subbu Venkatraman
Journal:  Drug Deliv Transl Res       Date:  2012-10       Impact factor: 4.617

Review 2.  Stimuli-responsive nanocarriers for intracellular delivery.

Authors:  Lemmuel L Tayo
Journal:  Biophys Rev       Date:  2017-11-25

3.  Antibacterial Activity of Polyaniline Coated in the Patterned Film Depending on the Surface Morphology and Acidic Dopant.

Authors:  Shahkar Falak; Bo Kyoung Shin; Do Sung Huh
Journal:  Nanomaterials (Basel)       Date:  2022-03-25       Impact factor: 5.076

4.  Poly(vinylidene fluoride-co-chlorotrifluoro ethylene) Nanohybrid Membrane for Fuel Cell.

Authors:  Karun Kumar Jana; Om Prakash; Vinod K Shahi; Devesh K Avasthi; Pralay Maiti
Journal:  ACS Omega       Date:  2018-01-24

5.  Fabrication of Low-Fouling Surfaces on Alkyne-Functionalized Poly-(p-xylylenes) Using Click Chemistry.

Authors:  Pei-Ju Chen; Hsien-Yeh Chen; Wei-Bor Tsai
Journal:  Polymers (Basel)       Date:  2022-01-06       Impact factor: 4.329

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.