Literature DB >> 21446033

In vivo 31P spectroscopy by fully adiabatic extended image selected in vivo spectroscopy: a comparison between 3 T and 7 T.

W Bogner1, M Chmelik, O C Andronesi, A G Sorensen, S Trattnig, S Gruber.   

Abstract

An improved image selected in vivo spectroscopy (ISIS) sequence for localized (31)P magnetic resonance spectroscopy at 7 T was developed. To reduce errors in localization accuracy, adiabatic excitation, gradient offset independent adiabatic inversion pulses, and a special extended ISIS ordering scheme were used. The localization accuracy of extended ISIS was investigated in phantoms. The possible spectral quality and reproducibility in vivo was explored in a volunteer (brain, muscle, and liver). A comparison between 3 T and 7 T was performed in five volunteers. Adiabatic extended ISIS provided high spectral quality and accurate localization. The contamination in phantom experiments was only ∼5%, even if a pulse repetition time ∼ 1.2·T(1) was chosen to maximize the signal-to-noise ratio per unit time. High reproducibility was found in the calf muscle for 2.5 cm isotropic voxels at 7 T. When compared with 3 T, localized (31)P magnetic resonance spectroscopy in the human calf muscle at 7 T provided ∼3.2 times higher signal-to-noise ratio (as judged from phosphocreatine peak amplitude in frequency domain after matched filtering). At 7 T, extended ISIS allowed the performance of high-quality localized (31)P magnetic resonance spectroscopy in a short measurement time (∼3 to 4 min) and isotropic voxel sizes of ∼2.5 to 3 cm. With such short measurement times, localized (31)P magnetic resonance spectroscopy has the potential to be applied not only for clinical research but also for routine clinical practice.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21446033     DOI: 10.1002/mrm.22897

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Three-dimensional mapping of the creatine kinase enzyme reaction rate in muscles of the lower leg.

Authors:  Prodromos Parasoglou; Ding Xia; Gregory Chang; Antonio Convit; Ravinder R Regatte
Journal:  NMR Biomed       Date:  2013-02-25       Impact factor: 4.044

2.  MRI of the hip at 7T: feasibility of bone microarchitecture, high-resolution cartilage, and clinical imaging.

Authors:  Gregory Chang; Cem M Deniz; Stephen Honig; Kenneth Egol; Ravinder R Regatte; Yudong Zhu; Daniel K Sodickson; Ryan Brown
Journal:  J Magn Reson Imaging       Date:  2013-09-23       Impact factor: 4.813

3.  Advanced MR methods at ultra-high field (7 Tesla) for clinical musculoskeletal applications.

Authors:  Siegfried Trattnig; Stefan Zbýň; Benjamin Schmitt; Klaus Friedrich; Vladimir Juras; Pavol Szomolanyi; Wolfgang Bogner
Journal:  Eur Radiol       Date:  2012-06-12       Impact factor: 5.315

4.  Spectrally selective 3D TSE imaging of phosphocreatine in the human calf muscle at 3 T.

Authors:  Prodromos Parasoglou; Ding Xia; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2012-04-12       Impact factor: 4.668

5.  Dynamic three-dimensional imaging of phosphocreatine recovery kinetics in the human lower leg muscles at 3T and 7T: a preliminary study.

Authors:  Prodromos Parasoglou; Ding Xia; Gregory Chang; Ravinder R Regatte
Journal:  NMR Biomed       Date:  2012-10-13       Impact factor: 4.044

6.  3D-mapping of phosphocreatine concentration in the human calf muscle at 7 T: comparison to 3 T.

Authors:  Prodromos Parasoglou; Ding Xia; Gregory Chang; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2013-02-06       Impact factor: 4.668

7.  Application of localized ³¹P MRS saturation transfer at 7 T for measurement of ATP metabolism in the liver: reproducibility and initial clinical application in patients with non-alcoholic fatty liver disease.

Authors:  Ladislav Valkovič; Martin Gajdošík; Stefan Traussnigg; Peter Wolf; Marek Chmelík; Christian Kienbacher; Wolfgang Bogner; Michael Krebs; Michael Trauner; Siegfried Trattnig; Martin Krššák
Journal:  Eur Radiol       Date:  2014-03-20       Impact factor: 5.315

8.  Comparison of Routine Brain Imaging at 3 T and 7 T.

Authors:  Elisabeth Springer; Barbara Dymerska; Pedro Lima Cardoso; Simon Daniel Robinson; Christian Weisstanner; Roland Wiest; Benjamin Schmitt; Siegfried Trattnig
Journal:  Invest Radiol       Date:  2016-08       Impact factor: 6.016

9.  Ultra-High-Field MRI in the Diagnosis and Management of Gliomas: A Systematic Review.

Authors:  Annabelle Shaffer; Susanna S Kwok; Anant Naik; Aaron T Anderson; Fan Lam; Tracey Wszalek; Paul M Arnold; Wael Hassaneen
Journal:  Front Neurol       Date:  2022-04-05       Impact factor: 4.003

10.  Noninvasive monitoring of training induced muscle adaptation with 31P-MRS: fibre type shifts correlate with metabolic changes.

Authors:  Eike Hoff; Lars Brechtel; Patrick Strube; Paul Konstanczak; Gisela Stoltenburg-Didinger; Carsten Perka; Michael Putzier
Journal:  Biomed Res Int       Date:  2013-07-15       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.