Literature DB >> 21443871

A novel, microscope based, non-invasive laser Doppler flowmeter for choroidal blood flow assessment.

C Strohmaier1, R M Werkmeister, B Bogner, C Runge, F Schroedl, H Brandtner, W Radner, L Schmetterer, J W Kiel, G Grabner, H A Reitsamer.   

Abstract

Impaired ocular blood flow is involved in the pathogenesis of numerous ocular diseases like glaucoma or AMD. The purpose of the present study was to introduce and validate a novel, microscope based, non-invasive Laser Doppler Flowmeter (NI-LDF) for measurement of blood flow in the choroid. The custom made NI-LDF was compared with a commercial fiber optic based laser Doppler flowmeter (Perimed PF4000). Linearity and stability of the NI-LDF were assessed in a silastic tubing model (i.d. 0.3 mm) at different flow rates (range 0.4-3 ml/h). In a rabbit model continuous choroidal blood flow measurements were performed with both instruments simultaneously. During blood flow measurements ocular perfusion pressure was changed by manipulations of intraocular pressure via intravitreal saline infusions. The NI-LDF measurement correlated linearly to intraluminal flow rates in the perfused tubing model (r = 0.99, p < 0.05) and remained stable during a 1 h measurement at a constant flow rate. Rabbit choroidal blood flow measured by the PF4000 and the NI-LDF linearly correlated with each other over the entire measurement range (r = 0.99, y = x∗1.01-12.35 P.U., p < 0.001). In conclusion, the NI-LDF provides valid, semi quantitative measurements of capillary blood flow in comparison to an established LDF instrument and is suitable for measurements at the posterior pole of the eye.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21443871      PMCID: PMC4572607          DOI: 10.1016/j.exer.2011.03.014

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  30 in total

1.  Blood flow in the human iris measured by laser Doppler flowmetry.

Authors:  S R Chamot; A M Movaffaghy; B L Petrig; C E Riva
Journal:  Microvasc Res       Date:  1999-03       Impact factor: 3.514

2.  In vivo evaluation of microcirculation by coherent light scattering.

Authors:  M D Stern
Journal:  Nature       Date:  1975-03-06       Impact factor: 49.962

3.  Higher order moment processing of laser Doppler perfusion signals.

Authors:  M L Arildsson; K Wardell; G E Nilsson
Journal:  J Biomed Opt       Date:  1997-10       Impact factor: 3.170

4.  Comparison of laser Doppler flowmeter and radioactive microspheres in measuring blood flow in pig skin flaps.

Authors:  R Rival; M Bance; O Antonyshyn; J Phillips; C Y Pang
Journal:  Laryngoscope       Date:  1995-04       Impact factor: 3.325

5.  In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry.

Authors:  A N Obeid
Journal:  Med Biol Eng Comput       Date:  1993-01       Impact factor: 2.602

6.  Local choroidal blood flow in the cat by laser Doppler flowmetry.

Authors:  C E Riva; S D Cranstoun; R M Mann; G E Barnes
Journal:  Invest Ophthalmol Vis Sci       Date:  1994-02       Impact factor: 4.799

7.  An instrument to measure cutaneous blood flow using the Doppler shift of laser light.

Authors:  D Watkins; G A Holloway
Journal:  IEEE Trans Biomed Eng       Date:  1978-01       Impact factor: 4.538

8.  Autoregulation of choroidal blood flow in the rabbit.

Authors:  J W Kiel; A P Shepherd
Journal:  Invest Ophthalmol Vis Sci       Date:  1992-07       Impact factor: 4.799

9.  Quantification of erythrocyte flow in the choroid of the albino rat.

Authors:  R D Braun; M W Dewhirst; D L Hatchell
Journal:  Am J Physiol       Date:  1997-03

10.  Choroidal blood flow in the foveal region of the human ocular fundus.

Authors:  C E Riva; S D Cranstoun; J E Grunwald; B L Petrig
Journal:  Invest Ophthalmol Vis Sci       Date:  1994-12       Impact factor: 4.799

View more
  2 in total

Review 1.  Is There Any Role for the Choroid in Glaucoma?

Authors:  Iman Goharian; Mitra Sehi
Journal:  J Glaucoma       Date:  2016-05       Impact factor: 2.503

2.  Compact Laser Doppler Flowmeter (LDF) Fundus Camera for the Assessment of Retinal Blood Perfusion in Small Animals.

Authors:  Marielle Mentek; Frederic Truffer; Christophe Chiquet; Diane Godin-Ribuot; Serge Amoos; Corinne Loeuillet; Mario Bernabei; Martial Geiser
Journal:  PLoS One       Date:  2015-07-30       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.