Literature DB >> 21443612

Platform switching and matrix metalloproteinase-8 levels in peri-implant sulcular fluid.

Luigi Canullo1, Giuliano Iannello, Lutz Netuschil, Søren Jepsen.   

Abstract

OBJECTIVES: The concept of platform switching has been introduced to implant therapy, however long-term data are sparse. The aim of this study was to biochemically investigate the inflammatory response mediated by MMP-8 to platform switching after 3 years of loading, in order to understand the long-term effect of implant/abutment mismatching on peri-implant health.
METHODS: A total of 70 implants had been inserted in the posterior maxilla in 26 patients and were randomly assigned to one of the four treatment regimens (implant diameter 3.8 [control group], 4.3 [Test group 1, T(1)], 4.8 [Test group 2, T(2)] and 5.5 mm [Test group 3, T(3)]). All implants were restored using a 3.8 mm abutment. In the test groups, this restoration resulted in a mismatching of 0.25-0.85 mm of implant-abutment diameters.
RESULTS: Thirty-six months after prosthetic rehabilitation, peri-implant sulcular fluid samples were taken from two aspects of all implants and from periodontally healthy adjacent teeth. Samples were processed in a conventional ELISA using monoclonal antibodies recognizing the active entity of MMP-8. In the test groups, MMP-8 mean values were 2.76 ng for T(1) (SD: 2.91), 3.30 ng for T(2) (SD: 1.94) and 3.18 ng for T(3) (SD: 2.46). For the control group, MMP-8 mean value was 3.6 ng (SD: 2.23), whereas 3.38 ng (SD: 2.2) was recorded at the adjacent teeth. There were no statistically significant differences in MMP-8 values between the groups (P=0.113, Kruskal-Wallis).
CONCLUSIONS: The presence of an implant/abutment mismatching specific for this prosthetic concept is compatible with long-term peri-implant health as demonstrated by analysis of a sensitive biomarker of the peri-implant inflammatory response.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21443612     DOI: 10.1111/j.1600-0501.2011.02175.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

1.  Analysis of Biomarkers and Marginal Bone Loss in Platform-Switched and Nonplatform-Switched Implants: A Randomized Clinical Trial.

Authors:  Necla Asli Kocak-Oztug; Gamze Zeynep Adem-Siyli; Orkhan Abishev; Sule Batu; Yegane Guven; Ali Cekici; Aslan Y Gokbuget; Erhan Firatli; Serdar Cintan
Journal:  Biomed Res Int       Date:  2022-05-21       Impact factor: 3.246

2.  An open prospective single cohort multicenter study evaluating the novel, tapered, conical connection implants supporting single crowns in the anterior and premolar maxilla: interim 1-year results.

Authors:  Alexander Fügl; Werner Zechner; Alessandro Pozzi; Guido Heydecke; Christine Mirzakhanian; Nikolaus Behneke; Alexandra Behneke; Russell A Baer; Robert Nölken; Edward Gottesman; Snjezana Colic
Journal:  Clin Oral Investig       Date:  2016-11-18       Impact factor: 3.573

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.