Literature DB >> 21441822

Virtual rheumatology: using simulators and a formal workshop to teach medical students, internal medicine residents, and rheumatology subspecialty residents arthrocentesis.

Ashley Gray Sterrett1, Helen Bateman, Jason Guthrie, Aasim Rehman, Vanessa Osting, John D Carter, Louis Ricca, Joanne Valeriano-Marcet.   

Abstract

BACKGROUND: Arthrocentesis is an important skill for medical practitioners at all levels of training. Previous studies have indicated a low comfort level and performance of arthrocentesis among primary care physicians that could be improved with hands-on training.
OBJECTIVES: The objective of this study was to improve comfort with knee and shoulder arthrocentesis at all levels of medical training, including medical students, internal medicine residents, and rheumatology subspecialty residents, and in arthrocentesis of the elbow, wrist, and ankle for advanced subspecialty residents in rheumatology through the use of a formal workshop using simulators.
METHODS: Fourth-year medical students and internal medicine residents were recruited from the University of South Florida. The rheumatology advanced subspecialty residents were participants from University of South Florida and from the American College of Rheumatology national meetings in 2008 and 2009. A 1-hour PowerPoint lecture followed by a hands-on practice session using Sawbones models (shoulder and knee for all groups, and elbow, wrist, and ankle additionally for the advanced subspecialty residents). A preworkshop self-assessment survey allowed the participant to rate his/her comfort level with arthrocentesis on a scale of 1 to 5. A survey with identical questions was completed immediately after the workshop. A follow-up survey was distributed by e-mail 3 to 6 months after the workshop.
RESULTS: One hundred forty-one medical students, 75 internal medicine residents, and 39 rheumatology subspecialty residents participated from January 2008 until January 2010. Mean comfort level in knee and shoulder arthrocentesis improved from preworkshop comfort level for all joints and among all participants. In addition, rheumatology subspecialty resident mean comfort level improved for ankle from 2.37 to 3.65, elbow from 2.56 to 3.80, and wrist from 2.31 to 3.77 (P < 0.0001).
CONCLUSIONS: Our study involved a very large number of participants encompassing different levels of training and is the largest number of advanced subspecialty rheumatology residents studied with regard to joint injection training. We have confirmed that a formal joint injection workshop using simulators is an effective method of improving comfort level in arthrocentesis among participants from all levels of medical training. Future studies should evaluate the effect of such training on actual clinical use and competence.

Entities:  

Mesh:

Year:  2011        PMID: 21441822     DOI: 10.1097/RHU.0b013e318214bb54

Source DB:  PubMed          Journal:  J Clin Rheumatol        ISSN: 1076-1608            Impact factor:   3.517


  4 in total

Review 1.  Sawbones laboratory in orthopedic surgical training.

Authors:  Bandar M Hetaimish
Journal:  Saudi Med J       Date:  2016-04       Impact factor: 1.484

2.  Ambulatory Training Program to Expand Procedural Skills in Primary Care.

Authors:  Robert J Fortuna; Bethany Marston; Susan Messing; Gunnar Wagoner; Tiffany L Pulcino; Todd Bingemann; Enrico Caiola; Steven Scofield; Karen Nead; Brett W Robbins
Journal:  J Med Educ Curric Dev       Date:  2019-07-01

3.  Randomized Controlled Study of a Training Program for Knee and Shoulder Arthrocentesis on Procedural Simulators with Assessment on Cadavers.

Authors:  Vincent Bretagne; Alice Delapierre; Damiano Cerasuolo; Anne Bellot; Christian Marcelli; Bernard Guillois
Journal:  ACR Open Rheumatol       Date:  2022-01-06

4.  An educational study to investigate the efficacy of three training methods for infiltration techniques on self-efficacy and skills of trainees in general practice.

Authors:  Nele R Michels; Els Vanhomwegen
Journal:  BMC Fam Pract       Date:  2019-09-14       Impact factor: 2.497

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.