Literature DB >> 21441390

Comparison of high sensitivity and contemporary troponin assays for the early detection of acute myocardial infarction in the emergency department.

Sally J Aldous1, Chris M Florkowski, Ian G Crozier, John Elliott, Peter George, John G Lainchbury, Richard J Mackay, Martin Than, Dylan Finlay Flaws, Jennifer Borowsky.   

Abstract

BACKGROUND: Current guidelines define acute myocardial infarction (AMI) by the rise and/or fall of cardiac troponin with ≥1 value above the 99th percentile. Past troponin assays have been unreliable at the lower end of the range. Highly sensitive assays have therefore been developed to increase the clinical sensitivity for detection of myocardial injury.
METHODS: Three hundred and thirty-two patients with chest pain suggestive of AMI were prospectively recruited between November 2006 and April 2007. Serial blood samples were analysed to compare Roche Elecsys high sensitivity troponin T (hsTnT), Abbott Architect troponin I 3rd generation (TnI 3) and Roche Elecsys troponin T (TnT) for the diagnosis of AMI.
RESULTS: One hundred and ten (33.1%) patients were diagnosed with AMI. Test performance for the diagnosis of AMI, as quantified by receiver operating characteristic area under the curve (95% confidence intervals) for baseline/follow-up troponins were as follows: hsTnT 0.90 (0.87-0.94)/0.94 (0.91-0.97), TnI 3 0.88 (0.84-0.92)/0.93 (0.90-0.96) and TnT 0.80 (0.74-0.85)/0.89 (0.85-0.94). hsTnT was superior to TnT (P < 0.001/0.013 at baseline/follow-up) but equivalent to TnI 3. For patients with a final diagnosis of AMI, baseline troponins were raised in more patients for hsTnT (83.6%) than TnI 3 (74.5%) and TnT (62.7%). A delta troponin of ≥20% increased the specificity of hsTnT from 80.6% to 93.7% but reduced sensitivity from 90.9% to 71.8%.
CONCLUSION: hsTnT was superior to TnT but equivalent to TnI 3 for the diagnosis of AMI. Serial troponin measurement increased test performance. hsTnT was the most likely to be raised at baseline in those with AMI. A delta troponin increases specificity but reduces sensitivity.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21441390     DOI: 10.1258/acb.2010.010219

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  13 in total

1.  Comparison of diagnostic accuracy between three different rules of interpreting high sensitivity troponin T results.

Authors:  Francesco Buccelletti; Leonarda Galiuto; Davide Marsiliani; Paolo Iacomini; Pierpaolo Mattogno; Annarita Carroccia; Chiara Cordischi; Simone Antonini; Elisa Fedele; Marta Sabbatini; Nicolò Gentiloni Silveri; Francesco Franceschi
Journal:  Intern Emerg Med       Date:  2012-05-23       Impact factor: 3.397

Review 2.  "Troponin elevation in coronary ischemia and necrosis".

Authors:  Stefan Agewall; Evangelos Giannitsis
Journal:  Curr Atheroscler Rep       Date:  2014-03       Impact factor: 5.113

3.  Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis.

Authors:  Ayman Al-Saleh; Ashraf Alazzoni; Saleh Al Shalash; Chenglin Ye; Lawrence Mbuagbaw; Lehana Thabane; Sanjit S Jolly
Journal:  CMAJ Open       Date:  2014-07-22

Review 4.  Novel Risk Stratification Assays for Acute Coronary Syndrome.

Authors:  Haitham M Ahmed; Stanley L Hazen
Journal:  Curr Cardiol Rep       Date:  2017-08       Impact factor: 2.931

Review 5.  Cardiac troponin level elevations not related to acute coronary syndromes.

Authors:  Evangelos Giannitsis; Hugo A Katus
Journal:  Nat Rev Cardiol       Date:  2013-08-27       Impact factor: 32.419

6.  Trimethyllysine, a trimethylamine N-oxide precursor, provides near- and long-term prognostic value in patients presenting with acute coronary syndromes.

Authors:  Xinmin S Li; Slayman Obeid; Zeneng Wang; Benjamin J Hazen; Lin Li; Yuping Wu; Alex G Hurd; Xiaodong Gu; Alan Pratt; Bruce S Levison; Yoon-Mi Chung; Steven E Nissen; Wai Hong Wilson Tang; François Mach; Lorenz Räber; David Nanchen; Christian M Matter; Thomas F Lüscher; Stanley L Hazen
Journal:  Eur Heart J       Date:  2019-08-21       Impact factor: 29.983

Review 7.  Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis.

Authors:  Zhivko Zhelev; Christopher Hyde; Emily Youngman; Morwenna Rogers; Simon Fleming; Toby Slade; Helen Coelho; Tracey Jones-Hughes; Vasilis Nikolaou
Journal:  BMJ       Date:  2015-01-20

Review 8.  Diagnostic accuracy of sensitive or high-sensitive troponin on presentation for myocardial infarction: a meta-analysis and systematic review.

Authors:  Ankur Sethi; Anurag Bajaj; Gurveen Malhotra; Rohit R Arora; Sandeep Khosla
Journal:  Vasc Health Risk Manag       Date:  2014-07-21

Review 9.  Troponin assay use in the emergency department for management of patients with potential acute coronary syndrome: current use and future directions.

Authors:  William R Fox; Deborah B Diercks
Journal:  Clin Exp Emerg Med       Date:  2016-03-31

10.  Transitioning high sensitivity cardiac troponin I (hs-cTnI) into routine diagnostic use: More than just a sensitivity issue.

Authors:  Graham R Lee; Tara Ca Browne; Berna Guest; Imran Khan; Eamon Murphy; Catherine McGorrian; Niall G Mahon; Maria C Fitzgibbon
Journal:  Pract Lab Med       Date:  2016-01-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.