Literature DB >> 21440694

Nuclear probes and intraoperative gamma cameras.

Sherman Heller1, Pat Zanzonico.   

Abstract

Gamma probes are now an important, well-established technology in the management of cancer, particularly in the detection of sentinel lymph nodes. Intraoperative sentinel lymph node as well as tumor detection may be improved under some circumstances by the use of beta (negatron or positron), rather than gamma detection, because the very short range (∼ 1 mm or less) of such particulate radiations eliminates the contribution of confounding counts from activity other than in the immediate vicinity of the detector. This has led to the development of intraoperative beta probes. Gamma camera imaging also benefits from short source-to-detector distances and minimal overlying tissue, and intraoperative small field-of-view gamma cameras have therefore been developed as well. Radiation detectors for intraoperative probes can generally be characterized as either scintillation or ionization detectors. Scintillators used in scintillation-detector probes include thallium-doped sodium iodide, thallium- and sodium-doped cesium iodide, and cerium-doped lutecium orthooxysilicate. Alternatives to inorganic scintillators are plastic scintillators, solutions of organic scintillation compounds dissolved in an organic solvent that is subsequently polymerized to form a solid. Their combined high counting efficiency for beta particles and low counting efficiency for 511-keV annihilation γ-rays make plastic scintillators well-suited as intraoperative beta probes in general and positron probes in particular Semiconductors used in ionization-detector probes include cadmium telluride, cadmium zinc telluride, and mercuric iodide. Clinical studies directly comparing scintillation and semiconductor intraoperative probes have not provided a clear choice between scintillation and ionization detector-based probes. The earliest small field-of-view intraoperative gamma camera systems were hand-held devices having fields of view of only 1.5-2.5 cm in diameter that used conventional thallium-doped sodium iodide or sodium-doped cesium iodide scintillation detectors. Later units used 2-dimensional arrays (mosaics) of scintillation crystals connected to a position-sensitive photomultiplier tube and, more recently, semiconductors such as cadmium telluride or cadmium zinc telluride. The main problems with the early units were their very small fields of view and the resulting large number of images required to interrogate the surgical field and the difficulty in holding the device sufficiently still for the duration (up to 1 min) of the image acquisition. More recently, larger field-of-view (up to 5 × 5 cm) devices have developed which are attached to an articulating arm for easy and stable positioning. These systems are nonetheless fully portable and small enough overall to be accommodated in typical surgical suites.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21440694     DOI: 10.1053/j.semnuclmed.2010.12.004

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  20 in total

1.  The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging.

Authors:  Patrick C McDaniel; Clarissa Zimmerman Cooley; Jason P Stockmann; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-06-23       Impact factor: 4.668

Review 2.  Sentinel lymph node biopsy in oral and oropharyngeal squamous cell carcinoma: current status and unresolved challenges.

Authors:  Christina Bluemel; Domenico Rubello; Patrick M Colletti; Remco de Bree; Ken Herrmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-04-28       Impact factor: 9.236

3.  Revolutionizing (robot-assisted) laparoscopic gamma tracing using a drop-in gamma probe technology.

Authors:  Matthias N van Oosterom; Hervé Simon; Laurent Mengus; Mick M Welling; Henk G van der Poel; Nynke S van den Berg; Fijs Wb van Leeuwen
Journal:  Am J Nucl Med Mol Imaging       Date:  2016-01-28

4.  Near-Infrared Intraoperative Chemiluminescence Imaging.

Authors:  Gabriel E Büchel; Brandon Carney; Travis M Shaffer; Jun Tang; Christine Austin; Manish Arora; Brian M Zeglis; Jan Grimm; Jörg Eppinger; Thomas Reiner
Journal:  ChemMedChem       Date:  2016-07-29       Impact factor: 3.466

5.  A Novel Technique for Generating and Observing Chemiluminescence in a Biological Setting.

Authors:  Gabriel E Büchel; Brandon Carney; Jun Tang; Brian M Zeglis; Jörg Eppinger; Thomas Reiner
Journal:  J Vis Exp       Date:  2017-03-09       Impact factor: 1.355

6.  Onboard functional and molecular imaging: a design investigation for robotic multipinhole SPECT.

Authors:  James Bowsher; Susu Yan; Justin Roper; William Giles; Fang-Fang Yin
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

Review 7.  Repurposing Molecular Imaging and Sensing for Cancer Image-Guided Surgery.

Authors:  Suman B Mondal; Christine M O'Brien; Kevin Bishop; Ryan C Fields; Julie A Margenthaler; Samuel Achilefu
Journal:  J Nucl Med       Date:  2020-04-17       Impact factor: 10.057

Review 8.  Cerenkov imaging.

Authors:  Sudeep Das; Daniel L J Thorek; Jan Grimm
Journal:  Adv Cancer Res       Date:  2014       Impact factor: 6.242

9.  Fusion of freehand SPECT and ultrasound: First experience in preoperative localization of sentinel lymph nodes.

Authors:  Christina Bluemel; Gonca Safak; Andreas Cramer; Achim Wöckel; Anja Gesierich; Elena Hartmann; Jan-Stefan Schmid; Franz Kaiser; Andreas K Buck; Ken Herrmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-06-17       Impact factor: 9.236

10.  The Utility of Intraoperative Handheld Gamma Camera for Detection of Sentinel Lymph Nodes in Melanoma.

Authors:  Elgin Ozkan; Aydan Eroglu
Journal:  Nucl Med Mol Imaging       Date:  2015-05-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.