| Literature DB >> 21439839 |
S Belousov1, M Mitev, K Ilieva, K Riley, O Harling.
Abstract
An optimization study of IRT-Sofia BNCT beam tube is presented. In the study we used the MIT/FCB experience. The enlarging of filter/moderator cross section dimensions and the decreasing of collimator length within the limits of the IRT-Sofia reactor design were analyzed. The influence of beam and reactor core axes non-coincidence on the beam properties was also evaluated. The irradiation resistance of polytetrafluoroethylene (Teflon(®)) was also evaluated. The results provide information for making decisions on the IRT-Sofia BNCT beam construction. Copyright ÂEntities:
Mesh:
Year: 2011 PMID: 21439839 DOI: 10.1016/j.apradiso.2011.03.001
Source DB: PubMed Journal: Appl Radiat Isot ISSN: 0969-8043 Impact factor: 1.513