Literature DB >> 21438088

Comparison of APPI, APCI and ESI for the LC-MS/MS analysis of bezafibrate, cyclophosphamide, enalapril, methotrexate and orlistat in municipal wastewater.

Araceli Garcia-Ac1, Pedro A Segura, Liza Viglino, Christian Gagnon, Sébastien Sauvé.   

Abstract

The applicability of three different ionization techniques: atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was tested for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of five target pharmaceuticals (cyclophosphamide, methotrexate, bezafibrate, enalapril and orlistat) in wastewater samples. Performance was compared both by flow injection analysis (FIA) and on-column analysis in deionized water and wastewater samples. A column switching technique for the on-line extraction and analysis of water samples was used. For both FIA and on-column analysis, signal intensity and signal-to-noise (S/N) ratio of the target analytes in the three sources were studied. Limits of detection and matrix effects during the analysis of wastewater samples were also investigated. ESI generated significantly larger peak areas and higher S/N ratios than APCI and APPI in FIA and in on-column analysis. ESI was proved to be the most suitable ionization method as it enabled the detection of the five target compounds, whereas APCI and APPI ionized only four compounds.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21438088     DOI: 10.1002/jms.1904

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  6 in total

Review 1.  Application of liquid chromatography-tandem mass spectrometry in quantitative bioanalyses of organic molecules in aquatic environment and organisms.

Authors:  Ugo Bussy; Ke Li; Weiming Li
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-21       Impact factor: 4.223

2.  Comparison of electrospray ionization and atmospheric chemical ionization coupled with the liquid chromatography-tandem mass spectrometry for the analysis of cholesteryl esters.

Authors:  Hae-Rim Lee; Sunil Kochhar; Soon-Mi Shim
Journal:  Int J Anal Chem       Date:  2015-03-19       Impact factor: 1.885

3.  Analysis of steroid hormones and their conjugated forms in water and urine by on-line solid-phase extraction coupled to liquid chromatography tandem mass spectrometry.

Authors:  A C Naldi; P B Fayad; M Prévost; S Sauvé
Journal:  Chem Cent J       Date:  2016-05-06       Impact factor: 4.215

4.  An ultrasensitive UHPLC-ESI-MS/MS method augmented with a controlled microwave derivatization reaction for quantitation of vitamin D3 and its major metabolites in COVID-19 patients.

Authors:  Sameh A Ahmed; Hani M J Khojah; Sultan S Al-Thagfan; Yaser M Alahmadi; Yasser A Mohammed
Journal:  Talanta       Date:  2022-04-22       Impact factor: 6.556

Review 5.  Occurrence of anticancer drugs in the aquatic environment: a systematic review.

Authors:  Carla Nassour; Stephen J Barton; Shereen Nabhani-Gebara; Yolande Saab; James Barker
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-12       Impact factor: 4.223

Review 6.  Analytical methodologies for determination of methotrexate and its metabolites in pharmaceutical, biological and environmental samples.

Authors:  Forough Karami; Sara Ranjbar; Younes Ghasemi; Manica Negahdaripour
Journal:  J Pharm Anal       Date:  2019-06-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.