Literature DB >> 21435478

Use of a hand-portable gas chromatograph-toroidal ion trap mass spectrometer for self-chemical ionization identification of degradation products related to O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX).

Philip A Smith1, Carmela R Jackson Lepage, Paul B Savage, Christopher R Bowerbank, Edgar D Lee, Michael J Lukacs.   

Abstract

The chemical warfare agent O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX) and many related degradation products produce poorly diagnostic electron ionization (EI) mass spectra by transmission quadrupole mass spectrometry. Thus, chemical ionization (CI) is often used for these analytes. In this work, pseudomolecular ([M+H](+)) ion formation from self-chemical ionization (self-CI) was examined for four VX degradation products containing the diisopropylamine functional group. A person-portable toroidal ion trap mass spectrometer with a gas chromatographic inlet was used with EI, and both fixed-duration and feedback-controlled ionization time. With feedback-controlled ionization, ion cooling (reaction) times and ion formation target values were varied. Evidence for protonation of analytes was observed under all conditions, except for the largest analyte, bis(diisopropylaminoethyl)disulfide which yielded [M+H](+) ions only with increased fixed ionization or ion cooling times. Analysis of triethylamine-d(15) provided evidence that [M+H](+) production was likely due to self-CI. Analysis of a degraded VX sample where lengthened ion storage and feedback-controlled ionization time were used resulted in detection of [M+H](+) ions for VX and several relevant degradation products. Dimer ions were also observed for two phosphonate compounds detected in this sample. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21435478     DOI: 10.1016/j.aca.2011.02.026

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Improved Miniaturized Linear Ion Trap Mass Spectrometer Using Lithographically Patterned Plates and Tapered Ejection Slit.

Authors:  Yuan Tian; Trevor K Decker; Joshua S McClellan; Linsey Bennett; Ailin Li; Abraham De la Cruz; Derek Andrews; Stephen A Lammert; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2017-08-23       Impact factor: 3.109

2.  Direct and Sensitive Detection of CWA Simulants by Active Capillary Plasma Ionization Coupled to a Handheld Ion Trap Mass Spectrometer.

Authors:  Jan-Christoph Wolf; Raphael Etter; Martin Schaer; Peter Siegenthaler; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-28       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.