Literature DB >> 21427587

The effect of age on the vestibular evoked myogenic potential and sternocleidomastoid muscle tonic electromyogram level.

Faith W Akin1, Owen D Murnane, Joanna W Tampas, Christopher G Clinard.   

Abstract

OBJECTIVE: Cervical vestibular evoked myogenic potentials (cVEMPs) are short-latency electromyogram (EMG) evoked by high-level acoustic stimuli recorded from the activated sternocleidomastoid muscle and used to evaluate otolith organ function. The purpose of this study was to investigate the effects of aging on the cVEMP and on the sternocleidomastoid muscle EMG level.
DESIGN: A cross-sectional observational study was used to investigate differences in cVEMP and sternocleidomastoid muscle EMG level in a group of 24 younger and 24 older individuals. cVEMPs were recorded during activation of the sternocleidomastoid muscle at target EMG levels ranging from 0 to 90 μV and during maximum voluntary contraction of the sternocleidomastoid muscle.
RESULTS: The sternocleidomastoid muscle EMG amplitude increased as a function of target EMG level for both age groups; however, the mean EMG amplitude was greater for the younger group than the older group, and the variability of EMG amplitude was greater for the older group. The EMG amplitude at maximum voluntary contraction ranged from 88 to 279 μV for the younger subjects and from 32 to 230 μV for the older subjects, and the mean EMG amplitude at maximum voluntary contraction was significantly greater for the younger group than the older group. The cVEMP amplitude increased as a function of EMG target level for each age group. Although cVEMP amplitude increased as a function of target EMG level for both groups, the older group exhibited smaller cVEMP amplitudes, overall, compared with the younger group. To separate the influence of EMG level from aging on cVEMP amplitude, only the responses obtained at the 30 μV target EMG level were considered for the statistical analysis because there was no significant difference in EMG level between groups at the 30 μV target level. The mean cVEMP amplitudes at the 30 μV target level were 101 and 51 μV for the younger and older groups, respectively, and a statistical analysis indicated that cVEMP amplitude for the younger group was significantly greater than the older group.
CONCLUSIONS: The findings suggest that the decrement in cVEMP amplitude is related to both age-related changes in the vestibular system and age-related changes in the sternocleidomastoid muscle.

Entities:  

Mesh:

Year:  2011        PMID: 21427587     DOI: 10.1097/AUD.0b013e318213488e

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  15 in total

1.  Characterization of age-related changes in sacculocolic response parameters assessed by cervical vestibular evoked myogenic potentials.

Authors:  Niraj Kumar Singh; Ranjitha S Kashyap; L Supreetha; V Sahana
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-08-28       Impact factor: 2.503

Review 2.  What vestibular tests to choose in symptomatic patients after a cochlear implant? A systematic review and meta-analysis.

Authors:  Moumainn Abouzayd; Paul F Smith; Sylvain Moreau; Martin Hitier
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-04-08       Impact factor: 2.503

3.  Downbeat nystagmus: evidence for enhancement of utriculo-ocular pathways by ocular vestibular evoked myogenic potentials?

Authors:  Tatiana Bremova; Stefan Glasauer; Michael Strupp
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-05-30       Impact factor: 2.503

4.  Epidemiology of vestibular evoked myogenic potentials: Data from the Baltimore Longitudinal Study of Aging.

Authors:  Carol Li; Andrew J Layman; John P Carey; Yuri Agrawal
Journal:  Clin Neurophysiol       Date:  2015-01-24       Impact factor: 3.708

5.  Postural sway in individuals with type 2 diabetes and concurrent benign paroxysmal positional vertigo.

Authors:  Linda J D'Silva; Patricia M Kluding; Susan L Whitney; Hongying Dai; Marcio Santos
Journal:  Int J Neurosci       Date:  2017-04-25       Impact factor: 2.292

6.  Association between hearing loss and saccular dysfunction in older individuals.

Authors:  Maria Geraldine Zuniga; Roni E Dinkes; Marcela Davalos-Bichara; John P Carey; Michael C Schubert; W Michael King; Jeremy Walston; Yuri Agrawal
Journal:  Otol Neurotol       Date:  2012-12       Impact factor: 2.311

7.  Effects of age on the tuning of the cVEMP and oVEMP.

Authors:  Erin G Piker; Gary P Jacobson; Robert F Burkard; Devin L McCaslin; Linda J Hood
Journal:  Ear Hear       Date:  2013 Nov-Dec       Impact factor: 3.570

8.  Aging of the Human Vestibular System.

Authors:  Christopher K Zalewski
Journal:  Semin Hear       Date:  2015-08

9.  Effect of aging on saccular function.

Authors:  Mehri Maleki; Zahra Jafari; Homa Zarrinkoob; Alireza Akbarzadeh Baghban
Journal:  Med J Islam Repub Iran       Date:  2014-10-22

Review 10.  The Effects of Aging on Clinical Vestibular Evaluations.

Authors:  Maxime Maheu; Marie-Soleil Houde; Simon P Landry; François Champoux
Journal:  Front Neurol       Date:  2015-09-22       Impact factor: 4.003

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.