Literature DB >> 21421197

Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve.

Cheng-Jing Tsai1, Kuang-Yi Tseng, Fu-Yuan Wang, I-Cheng Lu, Hsun-Mo Wang, Che-Wei Wu, Hui-Ching Chiang, Feng-Yu Chiang.   

Abstract

Intraoperative neuromonitoring (IONM) is widely used in thyroid surgery. This study aimed to investigate the influence of neck extension on electromyographic (EMG) endotracheal tube displacement and to determine the necessity of routinely checking the final electrode position after the patient had been fully positioned. A consecutive 220 patients undergoing thyroidectomy were enrolled. All patients were intubated with the EMG endotracheal tube under direct laryngoscopy. The electrode position and tube displacement were routinely checked and measured by laryngofiberoscopy before and after patient positioning. The patients were divided into two groups. In Group I (n=110), the EMG tube was taped and fixed to the right mouth angle before full neck extension. In Group II (n=110), the EMG tube was disconnected from the circuit tube and was not taped until full neck extension. In all patients, we ensured that the final electrode position was the optimal position with laryngofiberoscopic examination. The tube displacement after neck extension ranged from 16 mm upward to 4 mm downward in Group I and from 12 mm upward to 5 mm downward in Group II. The rate of tube displacement greater than 10 mm was 12.7% in Group I and 3.6% in Group II. Successful monitoring was achieved in all patients after the final optimal position of electrodes was ensured routinely. The electrode position can be severely displaced after the patient has been fully positioned. Verification of ideal position of electrodes before the beginning of the operation is a necessary step to guarantee functional intraoperative neuromonitoring.
Copyright © 2011 Elsevier Taiwan LLC. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21421197     DOI: 10.1016/j.kjms.2010.08.002

Source DB:  PubMed          Journal:  Kaohsiung J Med Sci        ISSN: 1607-551X            Impact factor:   2.744


  14 in total

1.  Recurrent laryngeal nerve injury with incomplete loss of electromyography signal during monitored thyroidectomy-evaluation and outcome.

Authors:  Che-Wei Wu; Min Hao; Mengzi Tian; Gianlorenzo Dionigi; Ralph P Tufano; Hoon Yub Kim; Kwang Yoon Jung; Xiaoli Liu; Hui Sun; I-Cheng Lu; Pi-Ying Chang; Feng-Yu Chiang
Journal:  Langenbecks Arch Surg       Date:  2016-02-17       Impact factor: 3.445

Review 2.  Loss of signal in recurrent nerve neuromonitoring: causes and management.

Authors:  Che-Wei Wu; Mei-Hui Wang; Cheng-Chien Chen; Hui-Chun Chen; Hsiu-Ya Chen; Jing-Yi Yu; Pi-Ying Chang; I-Cheng Lu; Yi-Chu Lin; Feng-Yu Chiang
Journal:  Gland Surg       Date:  2015-02

Review 3.  Intraoperative neural monitoring in thyroid surgery: lessons learned from animal studies.

Authors:  Che-Wei Wu; Gregory W Randolph; I-Cheng Lu; Pi-Ying Chang; Yi-Ting Chen; Pao-Chu Hun; Yi-Chu Lin; Gianlorenzo Dionigi; Feng-Yu Chiang
Journal:  Gland Surg       Date:  2016-10

4.  Drawbacks of neural monitoring troubleshooting algorithms in transoral endoscopic thyroidectomy.

Authors:  Daqi Zhang; Che-Wei Wu; Tie Wang; Yishen Zhao; Hoon Yub Kim; Antonella Pino; Gianlorenzo Dionigi; Hui Sun
Journal:  Langenbecks Arch Surg       Date:  2021-07-15       Impact factor: 3.445

Review 5.  Preoperative, intraoperative and postoperative anesthetic prospective for thyroid surgery: what's new.

Authors:  I-Cheng Lu; I-Hua Lin; Che-Wei Wu; Hsiu-Ya Chen; Yi-Chu Lin; Feng-Yu Chiang; Pi-Ying Chang
Journal:  Gland Surg       Date:  2017-10

6.  Modified arytenoid muscle electrode recording method for neuromonitoring during thyroidectomy.

Authors:  Peng Li; Qing-Zhuang Liang; Dong-Lai Wang; Bin Han; Xin Yi; Wei Wei
Journal:  Gland Surg       Date:  2019-10

7.  Trachway video intubating stylet allows for optimization of electromyographic endotracheal tube placement for monitored thyroidectomy.

Authors:  Pi-Ying Chang; Pin-Yang Hu; Yi-Chu Lin; Hsiu-Ya Chen; Feng-Yu Chiang; Che-Wei Wu; Gianlorenzo Dionigi; I-Cheng Lu
Journal:  Gland Surg       Date:  2017-10

8.  Proprieties of adhesive surface arrays to thyroid cartilage for recurrent laryngeal nerve monitoring.

Authors:  Yishen Zhao; Daqi Zhang; Le Zhou; Shijie Li; Tie Wang; Fang Li; Yujia Han; Gianlorenzo Dionigi; Hui Sun
Journal:  Ann Transl Med       Date:  2021-04

Review 9.  Optimization of Intraoperative Neural Monitoring of the Recurrent Laryngeal Nerve in Thyroid Surgery.

Authors:  Chia-Yuan Hsieh; Hao Tan; Hui-Fang Huang; Tzu-Yen Huang; Che-Wei Wu; Pi-Ying Chang; David-Vi Lu; I-Cheng Lu
Journal:  Medicina (Kaunas)       Date:  2022-03-30       Impact factor: 2.948

10.  Feasibility of Attachable Ring Stimulator for Intraoperative Neuromonitoring during Thyroid Surgery.

Authors:  Jongjin Kim; Hyeon Jong Moon; Young Jun Chai; Jung-Man Lee; Ki-Tae Hwang; Che-Wei Wu; Gianlorenzo Dionigi; Hoon Yub Kim; Kyung Sik Park; Sang Wan Kim; Ka Hee Yi
Journal:  Int J Endocrinol       Date:  2020-01-30       Impact factor: 3.257

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.