PURPOSE: To evaluate the advantages and disadvantages of the new low-addition (add) (+3.00 diopter [D]) ReSTOR multifocal IOL compared with the preceding ReSTOR model with +4.00 D add.
SETTING: University Eye Hospital, Tuebingen, Germany.
DESIGN: Comparative case series.
METHODS: Patients with a +3.00 D or +4.00 D add multifocal IOL were examined for uncorrected and distance-corrected visual acuity at distance, intermediate, and near. A defocus profile was assessed, individual reading distance and the distance for lowest intermediate visual acuity were determined. Patient satisfaction was evaluated with a standardized questionnaire. Contrast sensitivity was tested under mesopic and photopic conditions.
RESULTS: Uncorrected and distance-corrected intermediate visual acuities were statistically significantly better in the +3.00 D add group (24 eyes) than in the +4.00 D add group (30 eyes); distance and near visual acuities were not different between groups. The defocus profile significantly varied between groups. The +4.00 D add group had a closer reading distance (33.0 cm) than the +3.00 D add group (43.5 cm), a closer point of lowest intermediate visual acuity (65.8 cm versus 86.9 cm) and worse lowest intermediate visual acuity (20/59 ± 4.5 letters [SD] versus 20/48 ± 5.5 letters). Thus, patients in the +3.00 D add group reported being more satisfied with intermediate visual acuity. The +3.00 D add group reported more glare but less halos than the +4.00 D add group; contrast sensitivity was not different.
CONCLUSION: The lower addition resulted in a narrower defocus profile, a farther reading distance, and better intermediate visual acuity and thus increased patient satisfaction. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21420598     DOI: 10.1016/j.jcrs.2010.11.027

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Comparison of visual outcomes and reading performance after bilateral implantation of multifocal intraocular lenses with bilateral monofocal intraocular lenses.

Authors:  Özge Güngör Akkuş; Ikbal Seza Petriçli
Journal:  Int Ophthalmol       Date:  2017-05-18       Impact factor: 2.031

2.  [Clinical results of a multifocal pseudophakic additional lens].

Authors:  J Schrecker; A Langenbucher
Journal:  Ophthalmologe       Date:  2015-02       Impact factor: 1.059

3.  Visual and optical performances of multifocal intraocular lenses with three different near additions: 6-month follow-up.

Authors:  Mengmeng Wang; Christine Carole C Corpuz; Megumi Fujiwara; Minoru Tomita
Journal:  Open Ophthalmol J       Date:  2015-01-30

4.  Visual performance after the implantation of a new trifocal intraocular lens.

Authors:  Jérôme C Vryghem; Steven Heireman
Journal:  Clin Ophthalmol       Date:  2013-10-01

5.  Visual outcomes and patient satisfaction after refractive lens exchange with a single-piece diffractive multifocal intraocular lens.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2014-11-23       Impact factor: 1.909

6.  Comparison of visual outcomes, spectacles dependence and patient satisfaction of multifocal and accommodative intraocular lenses: innovative perspectives for maximal refractive-oriented cataract surgery.

Authors:  Raffaele Nuzzi; Federico Tridico
Journal:  BMC Ophthalmol       Date:  2017-02-14       Impact factor: 2.209

7.  Fractal-structured multifocal intraocular lens.

Authors:  Laura Remón; Salvador García-Delpech; Patricia Udaondo; Vicente Ferrando; Juan A Monsoriu; Walter D Furlan
Journal:  PLoS One       Date:  2018-07-09       Impact factor: 3.240

Review 8.  Continuous Transitional Focus (CTF): A New Concept in Ophthalmic Surgery.

Authors:  Ramón Ruiz Mesa; Tiago Monteiro
Journal:  Ophthalmol Ther       Date:  2018-06-18

9.  Comparison of three different diffractıve multifocal intraocular lenses with a +2.5, +3.0, and +3.75 diopter additıon power.

Authors:  Emre Altinkurt; Orkun Muftuoglu
Journal:  Saudi J Ophthalmol       Date:  2019-11-06

10.  Clinical outcomes after mix-and-match implantation of diffractive multifocal intraocular lenses with + 2.75 and + 4.00 diopter add powers.

Authors:  Jae Hyuck Lee; Hun Lee; Jin Ah Lee; Aeri Yoo; Jae Yong Kim; Hungwon Tchah
Journal:  BMC Ophthalmol       Date:  2020-05-15       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.