Literature DB >> 21419619

Optical detection systems using immobilized aptamers.

Audrey Sassolas1, Loïc J Blum, Béatrice D Leca-Bouvier.   

Abstract

Advances in the development and the applications of optical biosensing systems based on immobilized aptamers are presented. These nucleic acid sequences have been used as new molecular recognition elements to develop heterogeneous assays, biosensors and microarrays. Among different detection modes that have been employed, optical ones which are described here are among the most used. Since their first report in 1996, numerous optical detection systems using aptamers and mainly based on fluorescence have been developed. Two main approaches have been used: label-based (using fluorophore, luminophore, enzyme, nanoparticles) or aptamer label-free detection systems (e.g. surface plasmon resonance, optical resonance). Most methods are based on a labeling approach. Some targets can be optically detected using not only colorimetry, chemiluminescence or the most developed fluorescence mode but also more recent non conventional optical methods such as surface plasmon-coupled directional emission (SPCDE). The first SPCDE-based aptasensor for thrombin detection has recently been reported in 2009. Aptasensors based on surface-enhanced Raman scattering spectroscopy (SERS) which presents advantages compared to fluorescence have also been described. Different label-free techniques have recently been shown to be suitable for developing performant aptasensors or aptamer-based microarrays, such as surface plasmon resonance (SPR), diffraction grating, evanescent-field-coupled (EFC) waveguide-mode, optical resonance or Brewster angle straddle interferometry (BASI). Important advances have been realized on optical aptamer-based detection systems that appear as highly efficient devices with enormous potential.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21419619     DOI: 10.1016/j.bios.2011.02.031

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  13 in total

1.  Point-of-care detection of Escherichia coli O157:H7 in water using AuNPs-based aptasensor.

Authors:  Vahid Soheili; Seyed Mohammad Taghdisi; Khalil Abnous; Mohsen Ebrahimi
Journal:  Iran J Basic Med Sci       Date:  2020-07       Impact factor: 2.699

2.  Neutralizing DNA aptamers against swine influenza H3N2 viruses.

Authors:  Manoosak Wongphatcharachai; Ping Wang; Shinichiro Enomoto; Richard J Webby; Marie R Gramer; Alongkorn Amonsin; Srinand Sreevatsan
Journal:  J Clin Microbiol       Date:  2012-10-17       Impact factor: 5.948

Review 3.  Applications of aptasensors in clinical diagnostics.

Authors:  Ping Hong; Wenli Li; Jinming Li
Journal:  Sensors (Basel)       Date:  2012-01-30       Impact factor: 3.847

Review 4.  Waveguide-mode sensors as aptasensors.

Authors:  Subash C B Gopinath; Koichi Awazu; Makoto Fujimaki
Journal:  Sensors (Basel)       Date:  2012-02-15       Impact factor: 3.576

Review 5.  Aptasensors Based on Whispering Gallery Mode Resonators.

Authors:  Gualtiero Nunzi Conti; Simome Berneschi; Silvia Soria
Journal:  Biosensors (Basel)       Date:  2016-07-16

6.  Highly sensitive detection of influenza virus with SERS aptasensor.

Authors:  Vladimir I Kukushkin; Nikita M Ivanov; Anastasia A Novoseltseva; Alexandra S Gambaryan; Igor V Yaminsky; Alexey M Kopylov; Elena G Zavyalova
Journal:  PLoS One       Date:  2019-04-25       Impact factor: 3.240

Review 7.  Nucleic acids for ultra-sensitive protein detection.

Authors:  Kris P F Janssen; Karel Knez; Dragana Spasic; Jeroen Lammertyn
Journal:  Sensors (Basel)       Date:  2013-01-21       Impact factor: 3.576

8.  Tetraphenylporphyrin as a protein label for triple detection analytical systems.

Authors:  Kamila Konopińska; Mariusz Pietrzak; Radosław Mazur; Elżbieta Malinowska
Journal:  Heliyon       Date:  2015-12-22

9.  The Detection of Helicobacter hepaticus Using Whispering-Gallery Mode Microcavity Optical Sensors.

Authors:  Mark E Anderson; Emily C O'Brien; Emily N Grayek; James K Hermansen; Heather K Hunt
Journal:  Biosensors (Basel)       Date:  2015-08-07

10.  Integrating Nanostructured Artificial Receptors with Whispering Gallery Mode Optical Microresonators via Inorganic Molecular Imprinting Techniques.

Authors:  G Denise Hammond; Adam L Vojta; Sheila A Grant; Heather K Hunt
Journal:  Biosensors (Basel)       Date:  2016-06-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.