Literature DB >> 21417840

Mitral valved stent implantation: an overview.

Tim Attmann1, Saskia Pokorny, Lucian Lozonschi, Anja Metzner, Martin Marcynski-Bühlow, Jan Schoettler, Jochen Cremer, Georg Lutter.   

Abstract

To date, transcatheter valve implantation is limited to the replacement of pulmonary and aortic valves. The aim of this study was to analyze a valved stent for minimally invasive implantation in the mitral position. A self-expanding mitral valved stent was designed for transapical implantation. Thirty pigs underwent off-pump mitral valved stent implantation with follow-up times of 60 minutes (n = 17) and seven days (n = 13). Transesophageal echocardiography and computed tomography were used to evaluate stent function and positioning. After valved stent deployment, accurate adjustment of the intra-annular position reduced paravalvular leakage in all animals. Accurate positioning was established in all but five animals. The average mean transvalvular gradient across the mitral valve and the left ventricular outflow tract recorded immediately after deployment, six hours and one week were 1.85 ± 0.95 mmHg, 3.45 ± 1.65 mmHg, 4.15 ± 2.3 mmHg and 1.35 ± 1.35 mmHg, 1.45 ± 0.7 mmHg, 1.9 ± 0.65 mmHg, respectively. No valved stent migration, embolization, systolic anterior movement or left ventricular outflow tract obstruction was observed. The mitral valved stent can be deployed in a reproducible manner to achieve reliable stent stability, minimal gradients across the left ventricular outflow tract and adequate stent function in acute and short term experimental settings.

Entities:  

Mesh:

Year:  2011        PMID: 21417840     DOI: 10.3109/13645706.2011.554559

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  4 in total

1.  Development of off-pump mitral valve replacement in a porcine model.

Authors:  Matthew J Gillespie; Chikashi Aoki; Satoshi Takebayashi; Toru Shimaoka; Jeremy R McGarvey; Robert C Gorman; Joseph H Gorman
Journal:  Ann Thorac Surg       Date:  2015-04       Impact factor: 4.330

2.  Simulation Based Design and Evaluation of a Transcatheter Mitral Heart Valve Frame.

Authors:  Melissa Young; Ahmet Erdemir; Samantha Stucke; Ryan Klatte; Brian Davis; Jose L Navia
Journal:  J Med Device       Date:  2012-09       Impact factor: 0.582

3.  Transapical mitral valve implantation: the Lutter valve.

Authors:  G Lutter; S Pokorny; D Frank; J Cremer; L Lozonschi
Journal:  Heart Lung Vessel       Date:  2013

4.  A comparative study of the morphology of mammalian chordae tendineae of the mitral and tricuspid valves.

Authors:  Jennifer Hutchison; Paul Rea
Journal:  Vet Rec Open       Date:  2015-11-26
  4 in total