Literature DB >> 21416648

Ultrasonography-guided fine-needle aspiration cytology for thyroid nodules: an emphasis on one-sampling and biopsy techniques.

Dong Wook Kim1, Hye Jung Choo, Ji Sung Park, Eun Joo Lee, Sang Hyo Kim, Soo Jin Jung, Ji Hwa Ryu.   

Abstract

The aim of this study was to assess the adequacy and efficacy of ultrasonography (US)-guided fine-needle aspiration cytology (US-FNAC) with one-sampling technique (only one specimen through a single needle pass was obtained during the procedure on each thyroid nodule in each study patient) for the cytological diagnosis of thyroid nodules. In this study, US-FNAC techniques, including "free two-hand," "mixed sampling," "flipping-extraction," and "single-needle-pass" procedures were used to collect thyroid cells from July 2007 to June 2009. The cytopathology results and patients' complications were reviewed retrospectively. Of the 1456 thyroid-nodule samples obtained from 977 patients (1.49 per patient), the incidence of adequate and inadequate samplings was 88.5% (1289/1456) and 11.5% (167/1456), respectively. After thyroid surgery in 396 patients, 568 nodules were confirmed as 353 papillary thyroid carcinomas including one diffuse sclerosing variant, five follicular thyroid carcinomas, three medullary thyroid carcinomas, one anaplastic thyroid carcinoma, one metastatic renal cell carcinoma, two poorly differentiated carcinomas, 17 follicular adenomas, two nodular thyroiditis, two pseudonodules related to thyroiditis, and 182 cases of nodular hyperplasia. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, false-negative rate, and false-positive rate for the US-FNAC were 94.3%, 91.9%, 96.2%, 88.3%, 93.6%, 3.9%, and 2.6%, respectively. There were no significant patients' complications, but 87 patients (8.9%) reported mild pain during or after the procedure. This study showed a good adequacy and efficacy of US-FNAC for thyroid nodules despite one-sampling.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21416648     DOI: 10.1002/dc.21669

Source DB:  PubMed          Journal:  Diagn Cytopathol        ISSN: 1097-0339            Impact factor:   1.582


  10 in total

1.  Comparison of sample adequacy, pain-scale ratings, and complications associated with ultrasound-guided fine-needle aspiration of thyroid nodules between two radiologists with different levels of experience.

Authors:  Yoo Jin Lee; Dong Wook Kim; Soo Jin Jung
Journal:  Endocrine       Date:  2013-02-21       Impact factor: 3.633

2.  Ultrasound-guided fine-needle aspiration of benign thyroid cysts or partially cystic thyroid nodules: a preliminary study for factors predicting successful collapse.

Authors:  Dong Wook Kim
Journal:  Endocrine       Date:  2013-04-07       Impact factor: 3.633

3.  Endocrine surgeon-performed US guided thyroid FNAC is accurate and efficient.

Authors:  Dhafir Al-azawi; G Bruce Mann; Rodney T Judson; Julie A Miller
Journal:  World J Surg       Date:  2012-08       Impact factor: 3.352

Review 4.  Fine Needle Aspiration in the Investigation of Thyroid Nodules.

Authors:  Joachim Feldkamp; Dagmar Führer; Markus Luster; Thomas J Musholt; Christine Spitzweg; Matthias Schott
Journal:  Dtsch Arztebl Int       Date:  2016-05-20       Impact factor: 5.594

5.  Elastography Evaluation of Benign Thyroid Nodules in Patients Affected by Hashimoto's Thyroiditis.

Authors:  Carlo Cappelli; Ilenia Pirola; Elena Gandossi; Annamaria Formenti; Barbara Agosti; Maurizio Castellano
Journal:  Int J Endocrinol       Date:  2015-07-27       Impact factor: 3.257

Review 6.  Ultrasound-guided fine needle aspiration of thyroid nodules: a consensus statement by the korean society of thyroid radiology.

Authors:  Young Hen Lee; Jung Hwan Baek; So Lyung Jung; Jin Young Kwak; Ji-hoon Kim; Jung Hee Shin
Journal:  Korean J Radiol       Date:  2015-02-27       Impact factor: 3.500

7.  Ultrasonographic Interval Changes in Solid Thyroid Nodules after Ultrasonography-Guided Fine-Needle Aspiration.

Authors:  Ik Jung Hwang; Dong Wook Kim; Yoo Jin Lee; Hye Jung Choo; Soo Jin Jung; Hye Jin Baek
Journal:  Korean J Radiol       Date:  2018-01-02       Impact factor: 3.500

8.  Utility of including BRAF mutation analysis with ultrasonographic and cytological diagnoses in ultrasonography-guided fine-needle aspiration of thyroid nodules.

Authors:  Da Som Kim; Dong Wook Kim; Young Jin Heo; Jin Wook Baek; Yoo Jin Lee; Hye Jung Choo; Young Mi Park; Ha Kyoung Park; Tae Kwun Ha; Do Hun Kim; Soo Jin Jung; Ji Sun Park; Ki Jung Ahn; Hye Jin Baek; Taewoo Kang
Journal:  PLoS One       Date:  2018-08-17       Impact factor: 3.240

9.  Diagnostic Efficacy of Ultrasound-Guided Fine Needle Aspiration Combined with the Bethesda System of Reporting.

Authors:  K Ajitha Kumari; Poonam D Jadhav; Chaya Prasad; N V Smitha; Annie Jojo; V D Manjula
Journal:  J Cytol       Date:  2019 Apr-Jun       Impact factor: 1.000

10.  Comparison of Clinical and Ultrasonographic Features of Poorly Differentiated Thyroid Carcinoma and Papillary Thyroid Carcinoma.

Authors:  Bo Zhang; Hui-Min Niu; Qiong Wu; Jiong Zhou; Yu-Xin Jiang; Xiao Yang; Jian-Chu Li; Rui-Na Zhao; Ming Wang; Kang-Ning Li; Shen-Ling Zhu; Yu Xia; Ding-Rong Zhong
Journal:  Chin Med J (Engl)       Date:  2016-01-20       Impact factor: 2.628

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.