Literature DB >> 21416519

Comprehensive molecular imaging of photolabile surface samples with synchronized dual-polarity time-of-flight mass spectrometry.

Chih-Hao Hsiao1, Chia-Wei Hong, Bo-Hong Liu, Chiu Wen Chen, Chih-Che Wu, Yi-Sheng Wang.   

Abstract

This work presents the unique features of a novel configuration of a synchronized dual-polarity time-of-flight mass spectrometer for comprehensive surface imaging. Mass spectrometry imaging of surface samples covering positive and negative ion modes is difficult due to rapid signal depletion. This limitation is overcome here by dual-polarity time-of-flight mass spectrometry (DP-TOFMS) via two separate TOF mass analyzers that are installed above a sample surface. The new instrument eliminates the polarity bias characteristic of most mass spectrometers, which is important for the analysis of samples with diverse physical and chemical properties. The experimental results show for the first time that the spatial distribution of positive and negative ions of various photolabile samples can be distinguished, including pigments and conventional matrix-assisted laser desorption/ionization samples. The different positive and negative ion distributions suggest that accurate quantitative information can only be obtained when the entire sample region is examined by DP-TOFMS, which was unfeasible in the past. Such a comprehensive diagnostic method is essential for the molecular imaging of trace compositions in delicate biological tissues, as demonstrated here with a Phyllanthus urinaria leaf that only produced ion signals in the first examination and not in the subsequent measurements.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 21416519     DOI: 10.1002/rcm.4914

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  5 in total

1.  Preparation of Homogeneous MALDI Samples for Quantitative Applications.

Authors:  Yu-Meng Ou; Chien-Wei Tsao; Yin-Hung Lai; Hsun Lee; Huan-Tsung Chang; Yi-Sheng Wang
Journal:  J Vis Exp       Date:  2016-10-28       Impact factor: 1.355

2.  Reducing Spatial Heterogeneity of MALDI Samples with Marangoni Flows During Sample Preparation.

Authors:  Yin-Hung Lai; Yi-Hong Cai; Hsun Lee; Yu-Meng Ou; Chih-Hao Hsiao; Chien-Wei Tsao; Huan-Tsung Chang; Yi-Sheng Wang
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-28       Impact factor: 3.109

3.  Dual-Polarity Ion Trap Mass Spectrometry: Dynamic Monitoring and Controlling Gas-phase Ion-Ion Reactions.

Authors:  Muyi He; You Jiang; Dan Guo; Xingchuang Xiong; Xiang Fang; Wei Xu
Journal:  J Am Soc Mass Spectrom       Date:  2017-05-25       Impact factor: 3.109

4.  Dual-polarity SALDI FT-ICR MS imaging and Kendrick mass defect data filtering for lipid analysis.

Authors:  Wendy H Müller; Alexandre Verdin; Christopher Kune; Johann Far; Edwin De Pauw; Cedric Malherbe; Gauthier Eppe
Journal:  Anal Bioanal Chem       Date:  2020-10-30       Impact factor: 4.142

Review 5.  Mass spectrometry imaging for plant biology: a review.

Authors:  Berin A Boughton; Dinaiz Thinagaran; Daniel Sarabia; Antony Bacic; Ute Roessner
Journal:  Phytochem Rev       Date:  2015-10-13       Impact factor: 5.374

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.