Literature DB >> 21416027

Storage of Blood Components Does Not Decrease Haemostatic Potential: In vitro Assessment of Fresh versus Stored Blood Components Using Thromboelastography.

Galia Bartfeld1, Martin Ellis, Aharon Lubetzky, Vered Yahalom, Gili Kenet.   

Abstract

SUMMARY:
BACKGROUND: Major surgery and severe trauma typically lead to massive blood loss requiring rapid transfusion of large amounts of blood products. It has been suggested that fresh, unrefrigerated whole blood provides a haemostatic advantage in this setting. The aim of the current study was to compare the clot formation parameters of fresh, unrefrigerated whole blood and whole blood reconstituted from components stored for varying periods of time, using rotational thromboelastography (ROTEM®).
METHODS: Fresh whole blood and reconstituted whole blood using combinations of non-leucoreduced red cell units (stored for 7, 14, 21, 28, or 35 days), platelet concentrates (stored for 1, 3 or 5 days), and fresh frozen plasma (stored for 6 months) were analysed using ROTEM. Measurements of the clotting time (CT), clot formation time (CFT), and maximal clot firmness (MCF) were compared between units of fresh whole blood and reconstituted whole blood samples.
RESULTS: There was no difference in the haemostatic parameters measured of fresh whole blood and reconstituted whole blood using red cell units stored for less than 21 days. ROTEM demonstrated that the CT and CFT were significantly shorter for reconstituted whole blood samples using red cells stored for longer than 21 days when compared to fresh whole blood and to reconstituted whole blood samples using red cell units stored for less than 21 days. The CT was inversely correlated to the duration of platelet storage. The MCF was unchanged regardless of duration of blood product storage.
CONCLUSION: Fresh unrefrigerated whole blood and blood products stored for short duration (less than 21 days) were not superior to those stored for longer durations.

Entities:  

Year:  2010        PMID: 21416027      PMCID: PMC3048943          DOI: 10.1159/000322256

Source DB:  PubMed          Journal:  Transfus Med Hemother        ISSN: 1660-3796            Impact factor:   3.747


  18 in total

1.  The effect of storage on the expression of platelet membrane phosphatidylserine and the subsequent impacton the coagulant function of stored platelets.

Authors:  S Shapira; Z Friedman; H Shapiro; K Presseizen; J Radnay; M H Ellis
Journal:  Transfusion       Date:  2000-10       Impact factor: 3.157

Review 2.  The use of fresh whole blood in massive transfusion.

Authors:  Thomas B Repine; Jeremy G Perkins; David S Kauvar; Lorne Blackborne
Journal:  J Trauma       Date:  2006-06

Review 3.  Warm fresh whole blood transfusion for severe hemorrhage: U.S. military and potential civilian applications.

Authors:  Philip C Spinella
Journal:  Crit Care Med       Date:  2008-07       Impact factor: 7.598

4.  Length of storage of transfused red cells and postoperative morbidity in patients undergoing coronary artery bypass graft surgery.

Authors:  E C Vamvakas; J H Carven
Journal:  Transfusion       Date:  2000-01       Impact factor: 3.157

5.  Use of unrefrigerated fresh whole blood in massive transfusion.

Authors:  W N Erber; J Tan; D Grey; J A Lown
Journal:  Med J Aust       Date:  1996-07-01       Impact factor: 7.738

6.  Association of mortality with age of blood transfused in septic ICU patients.

Authors:  F R Purdy; M G Tweeddale; P M Merrick
Journal:  Can J Anaesth       Date:  1997-12       Impact factor: 5.063

Review 7.  Exsanguination in trauma: A review of diagnostics and treatment options.

Authors:  L M G Geeraedts; H A H Kaasjager; A B van Vugt; J P M Frölke
Journal:  Injury       Date:  2009-01-08       Impact factor: 2.586

8.  S-nitrosohemoglobin deficiency: a mechanism for loss of physiological activity in banked blood.

Authors:  James D Reynolds; Gregory S Ahearn; Michael Angelo; Jian Zhang; Fred Cobb; Jonathan S Stamler
Journal:  Proc Natl Acad Sci U S A       Date:  2007-10-11       Impact factor: 11.205

Review 9.  New assays for monitoring haemophilia treatment.

Authors:  M Shima; T Matsumoto; K Ogiwara
Journal:  Haemophilia       Date:  2008-07       Impact factor: 4.287

10.  Laboratory investigation of hypercoagulability in cancer patients using rotation thrombelastography.

Authors:  O Meltem Akay; Zeki Ustuner; Zerrin Canturk; Fezan Sahin Mutlu; Zafer Gulbas
Journal:  Med Oncol       Date:  2008-11-20       Impact factor: 3.064

View more
  2 in total

1.  Comparison of in vitro responses to fresh whole blood and reconstituted whole blood after collagen stimulation.

Authors:  Ina Nepstad; Håkon Reikvam; Geir Strandenes; John R Hess; Torunn O Apelseth; Tor A Hervig
Journal:  Blood Transfus       Date:  2013-10-24       Impact factor: 3.443

Review 2.  Optimal management of the critically ill: anaesthesia, monitoring, data capture, and point-of-care technological practices in ovine models of critical care.

Authors:  Saul Chemonges; Kiran Shekar; John-Paul Tung; Kimble R Dunster; Sara Diab; David Platts; Ryan P Watts; Shaun D Gregory; Samuel Foley; Gabriela Simonova; Charles McDonald; Rylan Hayes; Judith Bellpart; Daniel Timms; Michelle Chew; Yoke L Fung; Michael Toon; Marc O Maybauer; John F Fraser
Journal:  Biomed Res Int       Date:  2014-03-25       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.