Literature DB >> 21414435

Optimised determinations of water in ethanol by encoded photometric near-infrared spectroscopy: a special case of sequential standard addition calibration.

Richard J C Brown1, Adam C Keates, Andrew S Brown.   

Abstract

A special limiting case of sequential standard addition calibration (S-SAC) has been applied to measurement of the water content of ethanol using encoded photometric near infrared spectroscopy. The method has shown good comparability with certified reference materials and to measurements made by Karl Fischer titration. The technique is quick and easy to use and should have application in high throughput and process measurement, for instance in biofuels analysis at port-of-entry or in bio-refineries. The characteristics of this limiting case of S-SAC have been fully described, and the corrections required to the value obtained by extrapolation to avoid bias have been calculated. The precision of the S-SAC procedure has been studied, and proposals have been made to optimise this with respect to the analytical precision. The technique should be applicable for the measurement of water in ethanol mass fractions of up to 0.1g g(-1) with an expanded uncertainty of less than 2% (relative).
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Year:  2011        PMID: 21414435     DOI: 10.1016/j.aca.2011.02.002

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  In-line measurement of water content in ethanol using a PVA-coated quartz crystal microbalance.

Authors:  Byoung Chul Kim; Takuji Yamamoto; Young Han Kim
Journal:  Sensors (Basel)       Date:  2014-01-16       Impact factor: 3.576

2.  In-Line Measurement of Water Contents in Ethanol Using a Zeolite-Coated Quartz Crystal Microbalance.

Authors:  Byoung Chul Kim; Takuji Yamamoto; Young Han Kim
Journal:  Sensors (Basel)       Date:  2015-10-27       Impact factor: 3.576

Review 3.  Traditional Calibration Methods in Atomic Spectrometry and New Calibration Strategies for Inductively Coupled Plasma Mass Spectrometry.

Authors:  Jake A Carter; Ariane I Barros; Joaquim A Nóbrega; George L Donati
Journal:  Front Chem       Date:  2018-11-13       Impact factor: 5.221

4.  Monitoring the quality of ethanol-based hand sanitizers by low-cost near-infrared spectroscopy.

Authors:  Celio Pasquini; Maria C Hespanhol; Kaíque A M L Cruz; Alexandre F Pereira
Journal:  Microchem J       Date:  2020-08-17       Impact factor: 4.821

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.