Literature DB >> 21412924

Comparison of nuchal translucency measurements obtained using Volume NT(TM) and two- and three-dimensional ultrasound.

H Y Cho1, J-Y Kwon, Y H Kim, K H Lee, J Kim, S Y Kim, Y W Park.   

Abstract

OBJECTIVE: To evaluate the feasibility of Volume NT(TM) , a new technique that automatically archives mid-sagittal plane views and measures the maximum nuchal translucency (NT) thickness, by comparing its measurements with those made with conventional two- (2D) and three-dimensional (3D) techniques.
METHODS: This was a prospective study of 130 singleton pregnancies undergoing NT screening at 11 + 0 to 13 + 6 weeks of gestation. Fetuses with enlarged NT or multiple anomalies and those in the prone position were excluded. Success rate of NT measurement was assessed using Volume NT(TM) , 2D and 3D techniques. In cases in which all three techniques were successful, intra- and interobserver bias and levels of agreement for NT measurements within and between techniques were evaluated using Bland-Altman plots.
RESULTS: Of 130 cases enrolled into the study, 16 were excluded from analysis due to enlarged NT (n = 3), prone position (n = 2) or missing data (n = 11). Among the 114 cases analyzed, NT measurement was successful by the conventional 2D method in 95.6% (109/114) of cases and by 3D and Volume NT(TM) measurements in 103 and 93 cases, respectively. Success rate was not significantly different between methods. In 89 cases, NT values were available using all three methods. Among them, mean ± SD 2D-NT was 1.3 ± 0.4 mm, 3D-NT was 1.2 ± 0.4 mm and Volume NT(TM) was 1.3 ± 0.4 mm. The mean differences of the intra- and interobserver variability of each method were not significantly different from zero for each method.
CONCLUSIONS: Volume NT(TM) , a novel technique for automated NT measurement, is apparently reproducible and comparable with conventional 2D and 3D ultrasound techniques for NT measurement.
Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 21412924     DOI: 10.1002/uog.8996

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  2 in total

1.  Feasibility of three-dimensional reconstruction and automated measurement of fetal long bones using 5D Long Bone.

Authors:  Hyewon Hur; Young Han Kim; Hee Young Cho; Yong Won Park; Hye-Sung Won; Mi-Young Lee; Bo Hyon Yun; Kwang Hee Lee; Sung Yoon Kim; Junsang Yoo; Ja-Young Kwon
Journal:  Obstet Gynecol Sci       Date:  2015-07-16

2.  Image Settings Affecting Nuchal Translucency Measurement Using Volume NT Software.

Authors:  Hee Young Cho; Young Han Kim; Yong Won Park; Sung Yoon Kim; Kwang Hee Lee; Joon Sang Yoo; Ja-Young Kwon
Journal:  Yonsei Med J       Date:  2015-09       Impact factor: 2.759