Literature DB >> 21412838

Thalamic stimulation for tremor: can target determination be improved?

Eric Bardinet1, Hayat Belaid, David Grabli, Marie-Laure Welter, Sara Fernandez Vidal, Damien Galanaud, Stéphane Derrey, Didier Dormont, Philippe Cornu, Jérôme Yelnik, Carine Karachi.   

Abstract

High frequency stimulation of the ventral intermedius nucleus (Vim) of the thalamus is successfully used for the treatment of postural tremor. Target coordinates are most commonly calculated using a statistical method. Here, we compare a statistical and an individual targeting method, using an histology-based three-dimensional deformable brain atlas which allows localization of the Vim on individual patient's MR images by adaptation of the atlas onto the patient's brain. Twenty-nine consecutive patients had electrodes implanted in the Vim uni-or bilaterally for severe essential tremor. Thirty-five targets were determined by calculating the statistical target and then using the deformable atlas to compute the individual target. Pythagorean distance between these targets was calculated. Statistical and individual targets were compared by double blind evaluation of perioperative stimulation effects. For most cases (n = 24), the Pythagorean distance was higher than 1.5 mm. In 79% of these cases, the definitive electrode was implanted using the position of the individual target. For the remaining cases (n = 11, distance < 1.5 mm), the definitive electrode was implanted according to the statistical target location in 73% of the cases. As a whole, when individual target was used, it was located at least 2 mm more medial than the statistical one in 86% cases. These results suggest that Vim target determination based on a statistical method might be inaccurate. In particular, laterality might be overestimated, leading to nonoptimal clinical results. In clinical practice, this means that microelectrode exploration during Vim surgery should include at least one trajectory more medial than the statistical target.
Copyright © 2010 Movement Disorder Society.

Entities:  

Mesh:

Year:  2010        PMID: 21412838     DOI: 10.1002/mds.23448

Source DB:  PubMed          Journal:  Mov Disord        ISSN: 0885-3185            Impact factor:   10.338


  3 in total

1.  Does the Use of Intraoperative Microelectrode Recording Influence the Final Location of Lead Implants in the Ventral Intermediate Nucleus for Deep Brain Stimulation?

Authors:  Sujan Reddy; Albert Fenoy; Erin Furr-Stimming; Mya Schiess; Raja Mehanna
Journal:  Cerebellum       Date:  2017-04       Impact factor: 3.847

Review 2.  Motor thalamus integration of cortical, cerebellar and basal ganglia information: implications for normal and parkinsonian conditions.

Authors:  Clémentine Bosch-Bouju; Brian I Hyland; Louise C Parr-Brownlie
Journal:  Front Comput Neurosci       Date:  2013-11-11       Impact factor: 2.380

3.  [The use of neuromodulation for the treatment of tremor].

Authors:  Damián Bendersky; Pablo Ajler; Claudio Yampolsky
Journal:  Surg Neurol Int       Date:  2014-08-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.