Literature DB >> 21411330

AB-BNCT beam shaping assembly based on 7Li(p,n)7Be reaction optimization.

D M Minsky1, A J Kreiner, A A Valda.   

Abstract

A numerical optimization of a Beam Shaping Assembly (BSA) for Accelerator Based-Boron Neutron Capture Therapy (AB-BNCT) has been performed. The reaction (7)Li(p,n)(7)Be has been considered using a proton beam on a lithium fluoride target. Proton energy and the dimensions of a simple BSA geometry have been varied to obtain a set of different configurations. The optimal configuration of this set is shown. Copyright Â
© 2011 Elsevier Ltd. All rights reserved.

Entities:  

Year:  2011        PMID: 21411330     DOI: 10.1016/j.apradiso.2011.02.047

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  3 in total

1.  Present status of Accelerator-Based BNCT.

Authors:  Andres Juan Kreiner; Javier Bergueiro; Daniel Cartelli; Matias Baldo; Walter Castell; Javier Gomez Asoia; Javier Padulo; Juan Carlos Suárez Sandín; Marcelo Igarzabal; Julian Erhardt; Daniel Mercuri; Alejandro A Valda; Daniel M Minsky; Mario E Debray; Hector R Somacal; María Eugenia Capoulat; María S Herrera; Mariela F Del Grosso; Leonardo Gagetti; Manuel Suarez Anzorena; Nicolas Canepa; Nicolas Real; Marcelo Gun; Hernán Tacca
Journal:  Rep Pract Oncol Radiother       Date:  2014-12-12

2.  Evaluation of radioactivity in the bodies of mice induced by neutron exposure from an epi-thermal neutron source of an accelerator-based boron neutron capture therapy system.

Authors:  Satoshi Nakamura; Shoji Imamichi; Kazuyoshi Masumoto; Masashi Ito; Akihisa Wakita; Hiroyuki Okamoto; Shie Nishioka; Kotaro Iijima; Kazuma Kobayashi; Yoshihisa Abe; Hiroshi Igaki; Kazuyoshi Kurita; Teiji Nishio; Mitsuko Masutani; Jun Itami
Journal:  Proc Jpn Acad Ser B Phys Biol Sci       Date:  2017       Impact factor: 3.493

3.  Characterization of the relationship between neutron production and thermal load on a target material in an accelerator-based boron neutron capture therapy system employing a solid-state Li target.

Authors:  Satoshi Nakamura; Hiroshi Igaki; Masashi Ito; Hiroyuki Okamoto; Shie Nishioka; Kotaro Iijima; Hiroki Nakayama; Mihiro Takemori; Shoji Imamichi; Tairo Kashihara; Kana Takahashi; Koji Inaba; Kae Okuma; Naoya Murakami; Yoshihisa Abe; Yuko Nakayama; Mitsuko Masutani; Teiji Nishio; Jun Itami
Journal:  PLoS One       Date:  2019-11-22       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.