| Literature DB >> 21409609 |
Ru-Song Zhao1, Cong Hu, Jia-Bin Zhou, Jin-Peng Yuan, Shan-Shan Wang, Xia Wang.
Abstract
In this paper, a simple and cheap method for the simultaneous preconcentration and sensitive determination of three hexabromocyclododecane (HBCD) diastereomers (α-, β-, and γ-HBCD) in environmental water samples has been developed. It was based on solid phase extraction (SPE) and rapid resolution liquid chromatography-electrospray tandem mass spectrometry. Bamboo charcoal, one kind of cheap material, was investigated and used as SPE adsorbent for the enrichment and determination of HBCD diastereomers. Related important parameters affecting extraction efficiencies, including type and volume of eluant, amount of sorbent, sample pH, flow rate, and sample volume, were investigated and optimized in detail. Under the optimum conditions, experimental data exhibited excellent linear relationships between peak area and concentrations over the range 0.1-10 μg L(-1). The limits of detection and precision were in the range of 0.005-0.015 μg L(-1) and 4.59-7.47%, respectively. The proposed method has been successfully applied for the trace analysis of HBCD diastereomers in real-world environmental water samples.Entities:
Year: 2011 PMID: 21409609 DOI: 10.1007/s00216-011-4857-y
Source DB: PubMed Journal: Anal Bioanal Chem ISSN: 1618-2642 Impact factor: 4.142