Literature DB >> 21403988

Micro-mobile foot compression device compared with pneumatic compression device.

Michael Dohm1, Kim M Williams, Tim Novotny.   

Abstract

BACKGROUND: A combination mechanical-pharmacologic regimen is an accepted prophylactic treatment against symptomatic venous thromboembolism for patients undergoing total hip and knee arthroplasties. Foot pumps have been recognized as effective mechanical devices. Research suggests pharmacologic prophylaxis for venous thromboembolism is associated with complications and foot pumps offer an adjunct or alternative approach. Presumably the effectiveness of foot pumps relate to enhancement of venous flow. QUESTIONS/PURPOSES: We compared an established foot pump system with a new mobile foot pump for their ability to influence mean peak venous velocity in the common femoral, popliteal, and posterior tibial veins.
METHODS: We evaluated 60 healthy subjects with the established and the novel foot-pump systems. Ultrasonography was used to measure baseline and peak venous velocity with mechanical compression. We constructed 95% confidence intervals (CI) on the mean differences between the two devices to establish equivalence limits. We compared ratios of peak velocity to resting velocity. Subjects subjectively rated the two foot pumps with respect to size, fit, and comfort.
RESULTS: The 95% CI test for equivalence of the mean differences between the two devices was inconclusive. The novel device augmented the venous velocity 11 times greater than the resting velocity in the posterior tibial vein and three times greater than the resting velocity in the popliteal vein. The established foot pump augmented the venous velocity 15 times greater than the resting velocity in the posterior tibial vein and four times greater than the resting velocity in the popliteal vein. The novel device rated better for size, fit, and comfort when compared with the established device.
CONCLUSIONS: The established foot pump tended to be associated with greater peak velocities; the novel device produced more consistent mean peak venous velocities and may be more acceptable to patients and caregivers.

Entities:  

Mesh:

Year:  2011        PMID: 21403988      PMCID: PMC3094631          DOI: 10.1007/s11999-011-1847-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

1.  The effect of the position of the limb on venous impulse foot pumps.

Authors:  P Fleming; P Fitzgerald; A Devitt; J Rice; P Murray
Journal:  J Bone Joint Surg Br       Date:  2000-04

2.  Pneumatic compression hemodynamics in total hip arthroplasty.

Authors:  G H Westrich; L M Specht; N E Sharrock; T P Sculco; E A Salvati; P M Pellicci; J F Trombley; M Peterson
Journal:  Clin Orthop Relat Res       Date:  2000-03       Impact factor: 4.176

3.  Effects of external pneumatic intermittent compression on fibrinolysis in man.

Authors:  F Allenby; L Boardman; J J Pflug; J S Calnan
Journal:  Lancet       Date:  1973-12-22       Impact factor: 79.321

4.  A randomised comparison of a foot pump and low-molecular-weight heparin in the prevention of deep-vein thrombosis after total knee replacement.

Authors:  D Warwick; J Harrison; S Whitehouse; A Mitchelmore; M Thornton
Journal:  J Bone Joint Surg Br       Date:  2002-04

5.  Thrombosis prevention after total hip arthroplasty: a prospective, randomized trial comparing a mobile compression device with low-molecular-weight heparin.

Authors:  Clifford W Colwell; Mark I Froimson; Michael A Mont; Merrill A Ritter; Robert T Trousdale; Knute C Buehler; Andrew Spitzer; Thomas K Donaldson; Douglas E Padgett
Journal:  J Bone Joint Surg Am       Date:  2010-03       Impact factor: 5.284

6.  Compliance in using a pneumatic compression device after total knee arthroplasty.

Authors:  Geoffrey H Westrich; Peter H Jhon; Pamela M Sánchez
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2003-03

7.  The efficacy of the A-V Impulse system in the treatment of posttraumatic swelling following ankle fracture: a prospective randomized controlled study.

Authors:  J Caschman; S Blagg; M Bishay
Journal:  J Orthop Trauma       Date:  2004-10       Impact factor: 2.512

8.  Increasing circulation in the lower limb under general anesthesia using the A-V impulse system.

Authors:  Hiroaki Urayama; Kenichi Tanaka; Daisuke Fukui; Seiji Kawasaki
Journal:  Angiology       Date:  2003 Nov-Dec       Impact factor: 3.619

9.  Mechanical prophylaxis of deep-vein thrombosis after total hip replacement a randomised clinical trial.

Authors:  R P Pitto; H Hamer; W Heiss-Dunlop; J Kuehle
Journal:  J Bone Joint Surg Br       Date:  2004-07

10.  Incidence of symptomatic venous thromboembolism after different elective or urgent surgical procedures.

Authors:  Richard H White; Hong Zhou; Patrick S Romano
Journal:  Thromb Haemost       Date:  2003-09       Impact factor: 5.249

View more
  6 in total

1.  The Effect of Daily Use of Plantar Mechanical Stimulation Through Micro-Mobile Foot Compression Device Installed in Shoe Insoles on Vibration Perception, Gait, and Balance in People With Diabetic Peripheral Neuropathy.

Authors:  Gu Eon Kang; Mohsen Zahiri; Brian Lepow; Nimrah Saleem; Bijan Najafi
Journal:  J Diabetes Sci Technol       Date:  2019-04-03

2.  Efficacy of micromobile foot compression device in increasing lower limb venous blood flow.

Authors:  Thomas Charles; Stephen Mackintosh; James Fingleton; Irene Braithwaite; Mark Weatherall; Richard Beasley
Journal:  Int J Vasc Med       Date:  2013-11-11

Review 3.  Chronic Plantar Fasciitis is Mediated by Local Hemodynamics: Implications for Emerging Therapies.

Authors:  Larry E Miller; Daniel L Latt
Journal:  N Am J Med Sci       Date:  2015-01

4.  The effects of shoe type on lower limb venous status during gait or exercise: A systematic review.

Authors:  Lucie Lerebourg; Maxime L'Hermette; Charlotte Menez; Jeremy Coquart
Journal:  PLoS One       Date:  2020-11-25       Impact factor: 3.240

5.  Feasibility and Safety of a Novel Leg Exercise Apparatus for Venous Thromboembolism Prophylaxis after Total Joint Arthroplasty of the Lower Extremities-A Pilot Study.

Authors:  Kenta Tanaka; Yukiyo Shimizu; Hiroshi Kamada; Shizu Aikawa; Hajime Mishima; Akihiro Kanamori; Tomofumi Nishino; Masataka Sakane; Naoyuki Ochiai; Masashi Yamazaki
Journal:  Tomography       Date:  2021-11-04

6.  Randomized controlled trial of Micro-Mobile Compression® on lactate clearance and subsequent exercise performance in elite male cyclists.

Authors:  Iñigo San Millán; Kristen Bing; Carrie Brill; John C Hill; Larry E Miller
Journal:  Open Access J Sports Med       Date:  2013-10-16
  6 in total