Literature DB >> 21401543

Evaluation of a single-use intubating videoscope (Ambu aScope ™) in three airway training manikins for oral intubation, nasal intubation and intubation via three supraglottic airway devices.

S Scutt1, N Clark, T M Cook, C Smith, T Christmas, L Coppel, K Crewdson.   

Abstract

We compared the Ambu aScope™ with a conventional fibrescope in two simulated settings. First, 22 volunteers performed paired oral and nasal fibreoptic intubations in three different manikins: the Laerdal Airway Trainer, Bill 1 and the Airsim (a total of 264 intubations). Second, 21 volunteers intubated the Airway Trainer manikin via three supraglottic airways: classic and intubating laryngeal mask airways and i-gel (a total of 66 intubations). Performance of the aScope was good with few failures and infrequent problems. In the first study, choice of fibrescope had an impact on the number of user-reported problems (p=0.004), and user-assessed ratings of ease of endoscopy (p<0.001) and overall usefulness (p<0.001), but not on time to intubate (p=0.19), or ease of railroading (p=0.72). The manikin chosen and route of endoscopy had more consistent effects on performance: best performance was via the nasal route in the Airway Trainer manikin. In the second study, the choice of fibrescope did not significantly affect any performance outcome (p=0.3), but there was a significant difference in the speed of intubation between the devices (p=0.02) with the i-gel the fastest intubation conduit (mean (SD) intubation time i-gel 18.5 (6.8) s, intubating laryngeal mask airway = 24.1 (11.2) s, classic laryngeal mask airway = 31.4 (32.5) s, p=0.02). We conclude that the aScope performs well in simulated fibreoptic intubation and (if adapted for untimed use) would be a useful training tool for both simulated fibreoptic intubation and conduit-assisted intubation. The choice of manikin and conduit are also important in the success of such training. This manikin study does not predict performance in humans and a clinical study is required.
© 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2011        PMID: 21401543     DOI: 10.1111/j.1365-2044.2011.06647.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

1.  Simulation study of nasotracheal and orotracheal fiberoptic intubation with the Aintree Intubation Catheter.

Authors:  Ryusuke Ueki; Nobuyasu Komasawa; Munetaka Hirose; Yoshiroh Kaminoh
Journal:  Acute Med Surg       Date:  2015-06-30

2.  Simulation-based airway research: The fast-track recipes?

Authors:  Premanath F Kotur; Madhuri S Kurdi; Kaushik Theerth; Tushar Chokshi
Journal:  Indian J Anaesth       Date:  2022-06-21

3.  Utility of the Aintree Intubation Catheter in fiberoptic tracheal intubation through the three types of intubating supraglottic airways: a manikin simulation study.

Authors:  Ryusuke Ueki; Nobuyasu Komasawa; Kenta Nishimoto; Takashi Sugi; Munetaka Hirose; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2013-10-17       Impact factor: 2.078

  3 in total