Literature DB >> 21398013

Implant insertional torque values predict outcomes.

Lee R Walker1, Gary A Morris, Paul J Novotny.   

Abstract

PURPOSE: To study the relationships between insertional torque values (ITVs) recorded during implant placement and implant healing times and cumulative survival rates.
MATERIALS AND METHODS: This retrospective study evaluated 174 Osseotite 6.0-mm-diameter, straight-wall, threaded dental implants (BIOMET 3i, Palm Beach Gardens, FL) placed in 172 consecutive patients by the primary author. All implants were placed immediately into mandibular first or second molar extraction sockets after extraction. ITVs were recorded at placement. Implants were evaluated 3 months after surgery before discharge to restorative dentists for restoration. The post-restorative follow-up ranged from 2 years 1 month to 4 years 8 months (median and mean of 3 years 1 month [SD, 4.95]).
RESULTS: Of the implants, 3% (n = 5) were removed at the time of surgical placement because of perceived clinical mobility of the implants within the osteotomies. The implants that were stable at the time of implant placement (n = 169) were placed into 1 of 3 groups relative to the specific ITVs at implant placement: group 1, low ITV, 29% (n = 49); group 2, medium ITV, 23% (n = 39); and group 3, high ITV, 48% (n = 81). Cumulative survival rates for each group were 86% for low ITV, 90% for medium ITV, and 96% for high ITV (P = .0302). At the scheduled 3 months' follow-up visit, 33% of the low ITVs, 21% of the medium ITVs, and 5% of the high ITVs required an additional 3 months of healing.
CONCLUSION: In this study ITVs measured through surgical handpieces during implant placement provided meaningful real-time feedback that aided the surgeon regarding implant survival and determining unloaded healing times on a case-by-case basis.
Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21398013     DOI: 10.1016/j.joms.2010.11.008

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  6 in total

1.  In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants.

Authors:  Luiz-Antônio-Borelli Barros; Caio-Fossalussa da Silva; Germana-de Villa Camargos; Elcio Marcantonio; Guilherme-José-Pimentel-Lopes de Oliveira; Luiz-Antônio-Borelli Barros-Filho
Journal:  J Clin Exp Dent       Date:  2022-02-01

2.  Biomechanical Stability of Dental Implants in Augmented Maxillary Sites: Results of a Randomized Clinical Study with Four Different Biomaterials and PRF and a Biological View on Guided Bone Regeneration.

Authors:  Troedhan Angelo; Wainwright Marcel; Kurrek Andreas; Schlichting Izabela
Journal:  Biomed Res Int       Date:  2015-04-12       Impact factor: 3.411

3.  Optimised Implant Selection Using Digital Volume Tomography (DVT) Osteodensitometry.

Authors:  Manfred Nilius; Jörg Winterhoff
Journal:  Case Rep Dent       Date:  2022-02-14

4.  Primary implant stability in augmented sinuslift-sites after completed bone regeneration: a randomized controlled clinical study comparing four subantrally inserted biomaterials.

Authors:  Angelo Troedhan; Izabela Schlichting; Andreas Kurrek; Marcel Wainwright
Journal:  Sci Rep       Date:  2014-07-30       Impact factor: 4.379

5.  Molar Septum Expansion with Osseodensification for Immediate Implant Placement, Retrospective Multicenter Study with Up-to-5-Year Follow-Up, Introducing a New Molar Socket Classification.

Authors:  Samvel Bleyan; João Gaspar; Salah Huwais; Charles Schwimer; Ziv Mazor; José João Mendes; Rodrigo Neiva
Journal:  J Funct Biomater       Date:  2021-11-25

6.  Osseodensification effect on implants primary and secondary stability: Multicenter controlled clinical trial.

Authors:  Edmara T P Bergamo; Abbas Zahoui; Raúl Bravo Barrera; Salah Huwais; Paulo G Coelho; Edward Dwayne Karateew; Estevam A Bonfante
Journal:  Clin Implant Dent Relat Res       Date:  2021-05-27       Impact factor: 3.932

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.