Literature DB >> 21396527

A practical method to determine the effective resolution in incoherent experimental electron tomography.

Hamed Heidari Mezerji1, Wouter Van den Broek, Sara Bals.   

Abstract

It is not straightforward to determine resolution for a 3D reconstruction when performing an electron tomography experiment. Different contributions such as missing wedge and misalignment add up and often influence the final resolution in an anisotropic manner. The conventional resolution measures can not be used for all of the reconstruction techniques, especially for iterative techniques which are more commonly used for electron tomography in materials science. Here we define a quantitative resolution measure that determines the resolution in three orthogonal directions of the reconstruction. As an application we use this measure to determine the optimum number of simultaneous iterative reconstruction technique (SIRT) iterations to reconstruct the gold nanoparticles, based on a high angle annular dark field STEM (HAADF-STEM) tilt series.
Copyright © 2011 Elsevier B.V. All rights reserved.

Year:  2011        PMID: 21396527     DOI: 10.1016/j.ultramic.2011.01.021

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  4 in total

1.  Electron tomography reveals details of the internal microstructure of desalination membranes.

Authors:  Tyler E Culp; Yue-Xiao Shen; Michael Geitner; Mou Paul; Abhishek Roy; Michael J Behr; Steve Rosenberg; Junsi Gu; Manish Kumar; Enrique D Gomez
Journal:  Proc Natl Acad Sci U S A       Date:  2018-08-13       Impact factor: 11.205

2.  Multi-functional Ultrasonic Micro-elastography Imaging System.

Authors:  Xuejun Qian; Teng Ma; Mingyue Yu; Xiaoyang Chen; K Kirk Shung; Qifa Zhou
Journal:  Sci Rep       Date:  2017-04-27       Impact factor: 4.379

3.  Progress towards a methodology for high throughput 3D reconstruction of soot nanoparticles via electron tomography.

Authors:  E Haffner-Staton; A LA Rocca; M W Fay
Journal:  J Microsc       Date:  2018-01-16       Impact factor: 1.758

4.  Parakeet: a digital twin software pipeline to assess the impact of experimental parameters on tomographic reconstructions for cryo-electron tomography.

Authors:  James M Parkhurst; Maud Dumoux; Mark Basham; Daniel Clare; C Alistair Siebert; Trond Varslot; Angus Kirkland; James H Naismith; Gwyndaf Evans
Journal:  Open Biol       Date:  2021-10-27       Impact factor: 6.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.