Literature DB >> 21396421

Donor-specific antibody against denatured HLA-A1: clinically nonsignificant?

Shalini Pereira1, Susan Perkins, Jar-How Lee, Wayne Shumway, William LeFor, Mayra Lopez-Cepero, Cynthia Wong, Amy Connolly, Jane C Tan, F Carl Grumet.   

Abstract

Pre-transplant screening of a woman with end-stage renal disease (ESRD) showed no anti-human leukocyte antigen (HLA) alloantibodies by anti-human globulin-complement-dependent cytotoxicity (AHG-CDC; class I) or enzyme-linked immunosorbent assay (class II). Following a negative AHG-CDC crossmatch, an HLA*01:01+ deceased donor (DD) kidney was transplanted in September 2005. Subsequent screening of pre-transplant serum by LABScreen Single Antigen (SA) array showed strong reactivity versus A*01:01. Despite that reactivity, at 5 years post-transplant, the patient has a serum creatinine of 1.6 mg/dl and has never experienced humoral or cellular rejection. Retrospective flow-cytometric crossmatch of pre- and post-transplant sera versus DD cells was negative. Rescreening of multiple pre- and post-transplant sera revealed anti-A1 reactivity persisting from the first through the last samples tested. The patient's anti-A1 was almost two fold more reactive with denatured A*01:01 FlowPRA SA beads after denaturation with acid treatment (pH 2.7) than with untreated beads. Parallel results were observed with pH 2.7 treated versus untreated A1+ T cells in FXM. These data highlight the difficulty in interpreting screening results obtained using bead arrays, because of antibodies that appear to recognize denatured but not native class I HLA antigens. We suggest that such bead-positive, flow cytometric crossmatch negative antibodies are not associated with humoral rejection, may not necessarily be detrimental to a graft, and deserve further evaluation before becoming a barrier to transplantation.
Copyright © 2011 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21396421     DOI: 10.1016/j.humimm.2011.02.012

Source DB:  PubMed          Journal:  Hum Immunol        ISSN: 0198-8859            Impact factor:   2.850


  18 in total

Review 1.  Sensitive solid-phase detection of donor-specific antibodies as an aid highly relevant to improving allograft outcomes.

Authors:  Gerald Schlaf; Beatrix Pollok-Kopp; Wolfgang W Altermann
Journal:  Mol Diagn Ther       Date:  2014-04       Impact factor: 4.074

2.  Conformational Variants of the Individual HLA-I Antigens on Luminex Single Antigen Beads Used in Monitoring HLA Antibodies: Problems and Solutions.

Authors:  Vadim Jucaud; Mepur H Ravindranath; Paul I Terasaki
Journal:  Transplantation       Date:  2017-04       Impact factor: 4.939

3.  Pretransplantation monitoring of HLA antibodies by complement dependent cytotoxicity and Luminex-based assays.

Authors:  Nataša Katalinić; Marina Fućak; Tajana Crnić; Milena Ćurković; Alma Starčević; Sanja Balen
Journal:  Wien Klin Wochenschr       Date:  2016-10-14       Impact factor: 1.704

Review 4.  Methodological aspects of anti-human leukocyte antigen antibody analysis in solid organ transplantation.

Authors:  Andrew L Lobashevsky
Journal:  World J Transplant       Date:  2014-09-24

5.  The significance of pretransplant donor-specific antibodies reactive with intact or denatured human leucocyte antigen in kidney transplantation.

Authors:  H G Otten; M C Verhaar; H P E Borst; M van Eck; W G J van Ginkel; R J Hené; A D van Zuilen
Journal:  Clin Exp Immunol       Date:  2013-09       Impact factor: 4.330

Review 6.  Luminex and antibody detection in kidney transplantation.

Authors:  Antonietta Picascia; Teresa Infante; Claudio Napoli
Journal:  Clin Exp Nephrol       Date:  2012-05-03       Impact factor: 2.801

7.  Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform.

Authors:  Mepur H Ravindranath; Edward J Filippone; Grace Mahowald; Carly Callender; Adarsh Babu; Susan Saidman; Soldano Ferrone
Journal:  Immunol Res       Date:  2018-10       Impact factor: 2.829

8.  Washing red cells after leucodepletion does not decrease human leukocyte antigen sensitization risk in patients with chronic kidney disease.

Authors:  Antony Aston; Rebecca Cardigan; Saber Bashir; Susan Proffitt; Helen New; Colin Brown; Ri Liesner; Sylvia Hennem; Helen Nulty; Olivia Shaw; Robert Vaughan; Jon Jin Kim; Lesley Rees
Journal:  Pediatr Nephrol       Date:  2014-04-29       Impact factor: 3.714

Review 9.  Interpreting Anti-HLA Antibody Testing Data: A Practical Guide for Physicians.

Authors:  Carrie A Schinstock; Manish J Gandhi; Mark D Stegall
Journal:  Transplantation       Date:  2016-08       Impact factor: 4.939

10.  Role and Value of Luminex(®)-Detected HLA Antibodies before and after Kidney Transplantation.

Authors:  Caner Süsal; Gerhard Opelz; Christian Morath
Journal:  Transfus Med Hemother       Date:  2013-05-06       Impact factor: 3.747

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.