Literature DB >> 21396403

Validation of a new tool for automatic assessment of tremor frequency from video recordings.

Zdenka Uhríková1, Otakar Sprdlík, Martina Hoskovcová, Arnošt Komárek, Olga Ulmanová, Václav Hlaváč, Chris D Nugent, Evžen Růžička.   

Abstract

We present a validation study for TremAn--a tool for automatic detection of tremor and measurement of its frequency from video recordings. To assess the validity of TremAn we designed a study consisting of tremor assessment from video, by accelerometry and by clinical evaluation using Fahn-Tolosa-Marin scale. 26 patients with essential tremor and 5 healthy volunteers underwent the examination in four standardized positions with focus on the hand tremor. Results showed that the frequencies of tremor measured with TremAn and with accelerometry are closely related, attaining agreement with less than 0.1 Hz difference in 80% and less than 0.5 Hz in 94% of measured samples. The reproducibility of frequency measurements using TremAn was comparable to the accelerometry, with the TremAn/accelerometry ratio of measurement error standard deviations equal to 0.99 (95% confidence interval (0.84, 1.17)).
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21396403     DOI: 10.1016/j.jneumeth.2011.02.033

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  6 in total

1.  Essential Palatal Tremor Synchronization: A Study by Video Record Numerical Analysis.

Authors:  André Pierre Legrand; Elodie Hainque; Emmanuel Roze; Marie Vidailhet; Emmanuelle Apartis
Journal:  Mov Disord Clin Pract       Date:  2015-02-16

2.  Accuracy of Smartphone Video for Contactless Measurement of Hand Tremor Frequency.

Authors:  Stefan Williams; Hui Fang; Samuel D Relton; David C Wong; Taimour Alam; Jane E Alty
Journal:  Mov Disord Clin Pract       Date:  2020-12-28

3.  Gait disorders in parkinsonian monkeys with pedunculopontine nucleus lesions: a tale of two systems.

Authors:  David Grabli; Carine Karachi; Emmanuelle Folgoas; Morgane Monfort; Dominique Tande; Stewart Clark; Olivier Civelli; Etienne C Hirsch; Chantal François
Journal:  J Neurosci       Date:  2013-07-17       Impact factor: 6.167

4.  Tensometric tremorography in high-precision medical diagnostic systems.

Authors:  Zoya Aleksanyan; Olga Bureneva; Nikolay Safyannikov
Journal:  Med Devices (Auckl)       Date:  2018-09-13

5.  Imaging Tremor Quantification for Neurological Disease Diagnosis.

Authors:  Yuichi Mitsui; Thi Thi Zin; Nobuyuki Ishii; Hitoshi Mochizuki
Journal:  Sensors (Basel)       Date:  2020-11-22       Impact factor: 3.576

6.  Hand tremor detection in videos with cluttered background using neural network based approaches.

Authors:  Xinyi Wang; Saurabh Garg; Son N Tran; Quan Bai; Jane Alty
Journal:  Health Inf Sci Syst       Date:  2021-07-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.