Literature DB >> 21395908

Sonographic measurement of cervical length and risk of preterm delivery.

Oya Demirci1, Ayşegül Ünal, Elif Demirci, Hamdullah Sözen, Yeşim Akdemir, Esra Boybek, Aktuğ Ertekin.   

Abstract

AIM: To study the relationship between cervical lengths measured by ultrasound and risk of preterm delivery. MATERIAL &
METHODS: We examined 209 women with singleton pregnancies. The inclusion criteria were women who presented with regular and painful contractions (≥2 contractions at intervals of 10 min for at least 1 h). Transvaginal scan was performed to measure the cervical length. The clinical management of the women, including hospitalization and administration of tocolytics, was determined by the attending obstetricians, who were blinded about cervical length. The primary outcome was delivery within 7 days of presentation.
RESULTS: Delivery within 7 days of presentation occurred in 19/209 (9%) of pregnancies who were presenting with regular and painful uterine contraction at 31 weeks of gestation, and this was inversely related to cervical length. Logistic regression analysis demonstrated that cervical length and history of abortion remain as significant contributors to predicting delivery within 7 days. Of the patients who presented with threatened preterm labor, 117 (56%) received tocolytics, and 92 (44%) did not. In the group with a cervical length of <15 mm, delivery within 7 days occurred in 15/21 (71.4%) who were treated with tocolytics and 2/5 (40%) that were managed expectantly.
CONCLUSION: Women with threatened preterm labor and a cervical length of <15 mm at presentation are at high risk of delivering preterm within 7 days. Sonographic measurement of cervical length helps to avoid over-diagnosis of preterm labor.
© 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.

Entities:  

Mesh:

Year:  2011        PMID: 21395908     DOI: 10.1111/j.1447-0756.2010.01440.x

Source DB:  PubMed          Journal:  J Obstet Gynaecol Res        ISSN: 1341-8076            Impact factor:   1.730


  3 in total

Review 1.  Relevance of the antenatal corticosteroids-to-delivery interval in the prevention of neonatal respiratory distress syndrome through the eyes of causal inference: a review and target trial.

Authors:  Isabelle Dehaene; Kristien Roelens; Koenraad Smets; Johan Decruyenaere
Journal:  Arch Gynecol Obstet       Date:  2021-08-30       Impact factor: 2.344

2.  Predictive factors for latency period in viable pregnancies complicated by preterm premature rupture of the membranes.

Authors:  Cihan Çetin; Selim Büyükkurt; Ercan Cömert; Ferda Özlü; Nilgün Bahar; Cansun Demir
Journal:  Turk J Obstet Gynecol       Date:  2015-03-15

3.  Reference range of the weekly uterine cervical length at 8 to 38 weeks of gestation in the center of Iran.

Authors:  Esmat Jafari-Dehkordi; Atoosa Adibi; Mehri Sirus
Journal:  Adv Biomed Res       Date:  2015-05-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.