Literature DB >> 21394959

An experimental model of tool mark striations in soft tissues produced by serrated blades.

Derrick J Pounder1, Lesley Cormack.   

Abstract

Stab wounds produced by serrated blades are generally indistinguishable from stab wounds produced by non-serrated blades, except when visible tool mark striations are left on severed cartilage. We explored the possibility that similar striations may be produced on the soft tissues of internal organs. Loin of beef, bovine kidney, and pig heart, liver, and aorta were each stabbed 20 times with a coarsely serrated blade. The walls of the stab tracks were exposed and documented by photography, cast with dental impression material, and the casts photographed. Striations were identified in all of the tissues in every stabbing, but their consistency and quality varied between tissues. Striations were most easily seen in liver, heart, and aorta. Tool mark striations in soft tissues other than cartilage have not been described in homicidal stabbings, likely because they have not been sought. We suggest that the walls of stab wound tracks should be exposed, and tissue striations should be sought as a means of identifying the weapon as having a serrated blade.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21394959     DOI: 10.1097/paf.0b013e3181edf2de

Source DB:  PubMed          Journal:  Am J Forensic Med Pathol        ISSN: 0195-7910            Impact factor:   0.921


  4 in total

1.  Characteristics and time-dependence of cut marks and blunt force fractures on costal cartilages: an experimental study.

Authors:  Laura Spagnoli; Alberto Amadasi; Michela Frustaci; Debora Mazzarelli; Davide Porta; Cristina Cattaneo
Journal:  Forensic Sci Med Pathol       Date:  2016-01-12       Impact factor: 2.007

2.  How taphonomic alteration affects the detection and imaging of striations in stab wounds.

Authors:  Sophie A Stanley; Sarah V Hainsworth; Guy N Rutty
Journal:  Int J Legal Med       Date:  2017-10-29       Impact factor: 2.686

3.  Insights to enhance the examination of tool marks in human cartilage.

Authors:  Matthias Weber; Anja Niehoff; Markus A Rothschild
Journal:  Int J Legal Med       Date:  2021-05-13       Impact factor: 2.686

4.  Application of 3D printing in assessment and demonstration of stab injuries.

Authors:  Gábor Simon; Dénes Tóth; Veronika Heckmann; Viktor Soma Poór
Journal:  Int J Legal Med       Date:  2022-06-03       Impact factor: 2.791

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.