Literature DB >> 21394773

Analytic expressions for the ultimate intrinsic signal-to-noise ratio and ultimate intrinsic specific absorption rate in MRI.

E Kopanoglu1, V B Erturk, E Atalar.   

Abstract

The ultimate intrinsic signal-to-noise ratio is the highest possible signal-to-noise ratio, and the ultimate intrinsic specific absorption rate provides the lowest limit of the specific absorption rate for a given flip angle distribution. Analytic expressions for ultimate intrinsic signal-to-noise ratio and ultimate intrinsic specific absorption rate are obtained for arbitrary sample geometries. These expressions are valid when the distance between the point of interest and the sample surface is smaller than the wavelength, and the sample is homogeneous. The dependence on the sample permittivity, conductivity, temperature, size, and the static magnetic field strength is given in analytic form, which enables the easy evaluation of the change in signal-to-noise ratio and specific absorption rate when the sample is scaled in size or when any of its geometrical or electrical parameters is altered. Furthermore, it is shown that signal-to-noise ratio and specific absorption rate are independent of the permeability of the sample. As a practical case and a solution example, a uniform, circular cylindrically shaped sample is studied.
Copyright © 2011 Wiley-Liss, Inc.

Mesh:

Year:  2011        PMID: 21394773     DOI: 10.1002/mrm.22830

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  An analytic expression for the ultimate intrinsic SNR in a uniform sphere.

Authors:  Hong-Hsi Lee; Daniel K Sodickson; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2018-04-22       Impact factor: 4.668

2.  Modeling Endovascular MRI Coil Coupling With Transmit RF Excitation.

Authors:  Madhav Venkateswaran; Orhan Unal; Samuel Hurley; Alexey Samsonov; Peng Wang; Sean B Fain; Krishna N Kurpad
Journal:  IEEE Trans Biomed Eng       Date:  2016-03-04       Impact factor: 4.538

3.  Complex B1 mapping and electrical properties imaging of the human brain using a 16-channel transceiver coil at 7T.

Authors:  Xiaotong Zhang; Pierre-Francois Van de Moortele; Sebastian Schmitter; Bin He
Journal:  Magn Reson Med       Date:  2012-06-12       Impact factor: 4.668

Review 4.  Novel materials in magnetic resonance imaging: high permittivity ceramics, metamaterials, metasurfaces and artificial dielectrics.

Authors:  Andrew Webb; Alena Shchelokova; Alexey Slobozhanyuk; Irena Zivkovic; Rita Schmidt
Journal:  MAGMA       Date:  2022-04-26       Impact factor: 2.310

Review 5.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014

6.  From complex B(1) mapping to local SAR estimation for human brain MR imaging using multi-channel transceiver coil at 7T.

Authors:  Xiaotong Zhang; Sebastian Schmitter; Pierre-Francois Van de Moortele; Jiaen Liu; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2013-03-11       Impact factor: 10.048

7.  Magnetic field strength dependent SNR gain at the center of a spherical phantom and up to 11.7T.

Authors:  Caroline Le Ster; Andrea Grant; Pierre-François Van de Moortele; Alejandro Monreal-Madrigal; Gregor Adriany; Alexandre Vignaud; Franck Mauconduit; Cécile Rabrait-Lerman; Benedikt A Poser; Kâmil Uğurbil; Nicolas Boulant
Journal:  Magn Reson Med       Date:  2022-07-18       Impact factor: 3.737

8.  A workflow for predicting temperature increase at the electrical contacts of deep brain stimulation electrodes undergoing MRI.

Authors:  Alireza Sadeghi-Tarakameh; Nur Izzati Huda Zulkarnain; Xiaoxuan He; Ergin Atalar; Noam Harel; Yigitcan Eryaman
Journal:  Magn Reson Med       Date:  2022-07-04       Impact factor: 3.737

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.